Panasonic WJ-ND400 Rack mounting positions, Extension unit unit number, Network Disk Recorder

Models: WJ-ND400

1 60
Download 60 pages 6.87 Kb
Page 24
Image 24
Rack mounting positions

ND400_Basic.book 24 ページ 2008年4月8日 火曜日 午後3時59分

Setting up the Rack

Rack mounting positions

When connecting multiple extension units (WJ-HDE400) to the recorder, place the recorder in the center of the rack.

Connect the recorder and the extension unit with the connection cable (1 m {39.4 "}) included with the extension unit.

Connection cable

(provided with extension unit)

Extension unit (unit number 5)

Requires 1 Unit

Extension unit (unit number 4)

Connection cable Requires 1 Unit

Network Disk

Recorder

Requires 1 Unit

Extension unit (unit number 1)

Requires 1 Unit

Extension unit (unit number 2)

Requires 1 Unit

Cable coil example

Extension unit (unit number 3)

At least 10 cm

Round cable coil

Note:

Install the recorder in the center of the rack, if using a rack. If you install the recorder at the top or bottom of the rack, the cable may not be long enough.

When installing the recorder in the rack, leave a space of 1 unit (44 mm {1.73 "}) above and below each unit.

Secure the connection cables to the extension unit using the cable clamp provided.

If the connection is poor, the system may become unstable and unable to record images.

Keep the cables as short as possible. Looped cables or large distances between pieces of equipment may cause malfunctions. Also, do not bend the cables more than 90º, wind the cables in a coil (10 cm {3.94 "} in diameter).

Refer to the Setup Instructions (PDF file) to check the unit numbers of connected extension units.

24

Page 24
Image 24
Panasonic WJ-ND400 manual Rack mounting positions, Extension unit unit number, Network Disk Recorder, Requires 1 Unit