Setting up the Rack
Rack mounting positions
When connecting multiple extension units
Connect the recorder and the extension unit with the connection cable (1 m {39.4 "}) included with the extension unit.
Connection cable
(provided with extension unit)
Extension unit (unit number 5)
Requires 1 Unit
Extension unit (unit number 4)
Requires 1 Unit
Network Disk
Recorder
Requires 1 Unit
Extension unit (unit number 1)
Requires 1 Unit
Extension unit (unit number 2)
Requires 1 Unit
Cable coil example
Extension unit (unit number 3)
At least 10 cm
Round cable coil
Note:
•Install the recorder in the center of the rack, if using a rack. If you install the recorder at the top or bottom of the rack, the cable may not be long enough.
•When installing the recorder in the rack, leave a space of 1 unit (44 mm {1.73 "}) above and below each unit.
•Secure the connection cables to the extension unit using the cable clamp provided.
If the connection is poor, the system may become unstable and unable to record images.
•Keep the cables as short as possible. Looped cables or large distances between pieces of equipment may cause malfunctions. Also, do not bend the cables more than 90º, wind the cables in a coil (10 cm {3.94 "} in diameter).
•Refer to the Setup Instructions (PDF file) to check the unit numbers of connected extension units.