About Connectors
Alarm/Control connector and Alarm Connector Timing and Polarity
Connectors | Active Time | Remarks |
|
|
|
Alarm input | 100 ms or more | L active |
|
|
|
Alarm output | The time set on the setup menu | L active |
|
|
|
Network error output | Until the network error is cleared, or until the [ERR] button on | L active |
| the operation window (browser) is clicked. |
|
|
|
|
Alarm reset input | 100 ms or more | L active |
|
|
|
Emergency recording input | 100 ms or more | L active |
|
|
|
Available disk space warning output | From the time of the error occurrence until the time of the | L active |
| error output duration* |
|
|
|
|
HDD error output | From the time of the error occurrence until the time of the | L active |
| error output duration* |
|
|
|
|
Camera error output | From the time of the error occurrence until the time of the | L active |
| error output duration or the camera is reset* |
|
|
|
|
Error output | From the time of the error occurrence until the time of the | L active |
| error output duration* |
|
|
|
|
Time adjustment input/output | Input: 100 ms or more | Input/Output: |
| Output: 1 s | L active |
|
|
|
Alarm suspension input | 100 ms or more | L active, judged level |
|
|
|
External recording mode switching | 100 ms or more | L active |
|
|
|
Outage detection input | 5 s or more | L active |
|
|
|
Power outage recovery completion | 10 s or more | H active |
output |
|
|
|
|
|
*The error output timing is set under [Basic] on the settings menu (refer to the Setup Instructions (PDF file)).
Note:
•During L active (Low active), the logic is enabled when the signal's voltage level is Low.
•During H active (High active), the logic is enabled when the signal's voltage level is High.