Panasonic WV-NP1000 manual Pulse width, Default OFF External terminal output setup, Default Open

Models: WV-NP1004 WV-NP1000

1 70
Download 70 pages 56.74 Kb
Page 30
Image 30

Configure the settings relating to the alarm out connector [Alarm output setup]

Click the [Alarm] tab on the "Alarm setup" page. (page 28)

The settings relating to the alarm out connector can be configured on this page. Refer to pages 29 and 30 for further information about the settings relating to the alarm image and the alarm out connector.

Note:

When "Close" is selected, the alarm signal will be output for around 1 minute when the power of the camera is turned on.

[Pulse width]

When "Pulse" is selected for "Alarm output", select an pulse width.

Available pulse width: 1 - 120 sec

Default: 1 sec

[Alarm output setup]

Select "ON" or "OFF" to determine whether or not to output the alarm signals to the alarm out connector when an alarm is detected.

Default: OFF

[External terminal output setup]

Select "Latch" or "Pulse" for the alarm out connector at an alarm occurrence.

Latch: When an alarm is detected, alarm output con- nector will be in the state selected for "Alarm output" until the [Alarm reset] button is clicked.

Pulse: When an alarm is detected, alarm output con- nector will be in the opposite state to the "Alarm out- put" setting for the period set for "Pulse width".

Default: Latch

[Alarm output]

Select "Open" or "Close" to determine whether to open or close the alarm output connector when output the alarm signals.

Open: The alarm out connector will open when output the alarm signals.

Close: The alarm out connector will close when output the alarm signals.

Default: Open

30

Page 30
Image 30
Panasonic WV-NP1000 Pulse width, Default OFF External terminal output setup, Default Latch Alarm output, Default Open