To define each DS0 Mapping you will create a static connection. “A” and “B” designate the two ends of the static connection. For each static connection you will define the following parameters:

Device Type. Specifies the physical interface type for the connection. You may select either t1-e1 (1) or none(0). Additionally, for Device Type B, there is an option for toH.110(5) and fromH.110(6), indi- cating direction of the T1/E1 DS0s mapped to the H.110 (TDM bus system).

Device Number. Defines which T1/E1 port number on the 2616RC you are mapping. For example, to map a connection for T1/E1 port 3 you would select port3(3).

Device Slots. Defines which DS0 channels will be mapped. Each DS0 channel is 64 kbps. Each T1port port has 24 DS0 channels. Each E1 WAN port has 32 DS0 channels. When defining time slots you must select the same number of Device Slots on the “A” and “B” sides of the connection. The slots are defined by entering a text string that represents the slots. For the T1/E1 ports, the slots that are available are 1–32. For a WAN port configured as a T1, the available slots are numbered from 1–24. For a WAN port configured as an E1, the available slots are 1–32. The H.110 (TDM system bus) is comprised of 32 ports; each port contains 128 unidirectional slots.

Examples for configuring static connections:

Example 1: Connecting DS0s from an E1 port to another E1 port within one card.

Example 2: Connecting DS0s from an E1 port on one card to an E1 port on another card via H.110 bus.

Example 1

Connect T1/E1 ports 1 and 10 to live E1 lines.

Solution:

1.Under Dev Type A, select t1-e1(1).

2.Under Dev Num A, select port1(1).

3.Under Dev Slots A, enter 1 - 32.

4.Under Dev Type B, select t1-e1(1).

5.Under Dev Num B, select port10(10).

6.Under Dev Slots B, enter 1 - 32.

7.Click the Submit Query button.

Example 2

Connect T1/E1 port 1 of card 1, and T1/E1 port 10 of card 2 to live E1 lines.

Solution:

Card one mapping

1.Under Dev Type A, select t1-e1(1).

2.Under Dev Num A, select port1(1).

3.Under Dev Slots A, enter 1 - 32.

4.Under Dev Type B, select toH110.

Using a browser to complete Model 2616RC configuration