Far End Line Statistics—Totals

Click on Far End Line Statistics—Totalsto display the total statistics of errors that occurred during the previous 24-hour period (see figure 51). This is the sum of the current 15-minute interval and all time prior intervals within the last 24 hours.

Figure 51. Far End Performance window

Errored Seconds (dsx1FarEndTotalESs)

The number of far-end errored seconds encountered by a DS1 interface in the previous 24-hour interval.

Severly Errored Seconds (dsx1FarEndTotalSESs)

The number of far-end severely errored seconds encountered by a DS1 interface in the previous 24-hour interval.

Severely Errored Frame Seconds (dsx1FarEndTotalSEFSs)

The number of far-end severely errored framing seconds encountered by a DS1 interface in the previous 24- hour interval.

Unavailable Seconds (dsx1FarEndTotalUASs)

The number of far-end unavailable seconds encountered by a DS1 interface in the previous 24-hour in-24- hour interval.

Controlled Slip Seconds (dsx1FarEndTotalCSSs)

The number of far-end controlled slip seconds encountered by a DS1 interface in the previous 24-hour interval.

Line Errored Seconds (dsx1FarEndTotalLESs)

The number of far-end line errored seconds encountered by a DS1 interface in the previous 24-hour interval.

Path Code Violations (dsx1FarEndTotalPCVs)

The number of far-end path coding violations reported via the far-end block error count encountered by a DS1 interface in the previous 24-hour interval.