17 • T1/E1 Link

T1/E1 DACS Administrators’ Reference Guide

 

 

Controlled Slip Seconds (dsx1FarEndCurrentCSSs)

The number of far-end controlled slip seconds encountered by a DS1 interface in the current 15-minute inter- val.

Line Errored Seconds (dsx1FarEndCurrentLESs)

The number of far-end line errored seconds encountered by a DS1 interface in the current 15-minute interval

Path Code Violations (dsx1FarEndCurrentPCVs)

The number of far-end path coding violations reported via the far-end block error count encountered by a DS1 interface in the current 15-minute interval.

Bursty Errored Seconds (dsx1FarEndCurrentBESs)

The number of far-end bursty errored seconds (BESs) encountered by a DS1 interface in the current 15- minute interval.

Degraded Minutes (dsx1FarEndCurrentDMs)

The number of far-end degraded minutes (DMs) encountered by a DS1 interface in the current 15-minute interval.

Far End Line Statistics—History

Click on Far End Line Statistics—Historyto display far-end statistics for previously completed 15-minute inter- vals (see figure 50).

Figure 50. History of Far End Performance window

132

Far End Line Statistics—History

Page 134
Image 134
Patton electronic Model 2604 manual Far End Line Statistics-History