6 • Clocking

T1/E1 DACS Administrators’ Reference Guide

 

 

Introduction

Click on Clocking in the Configuration Menu to display the System Clocking Configuration main window (see figure 15).

Figure 15. System Clocking Configuration window

The Clocking window is where the primary and secondary clocking sources that synchronize all DS0 channels are configured. The DACS uses a single clock source for all DS0 channels. You select the clock for the DS0 channels from the following clock sources:

An internal oscillator

Any of the WAN ports

An external clock (accessed via the Ext. Clock 3-position terminal block located on the rear panel of the DACS.”

The Main Reference setting determines the clock source if this source is operational. If the Main Reference clock source fails, the Fallback Reference becomes the clock source to synchronize all DS0 channels. The clock source is the system clock for the entire DACS.

Configuring the System Clock Settings

The following sections describe configuring the clock settings.

Main Reference (daxClockMainRef)

The Main Reference and Fallback Reference parameters have the same selections for system clock. Make sure you choose different clock sources for the Main Reference and Fallback Reference. The following settings are available:

none(0)—No clock selection.

wan-1(1)—WAN port #1 is the clock source

wan-2(2)—WAN port #2 is the clock source

wan-3(3)—WAN port #3 is the clock source

wan-4(4)—WAN port #4 is the clock source

wan-5(5)—N/A

wan-6(6)—N/A

wan-7(7)—N/A

wan-8(8)—N/A

42

Introduction

Page 44
Image 44
Patton electronic Model 2604 manual Configuring the System Clock Settings, Main Reference daxClockMainRef