ALARMS

PELCO EXSITE IPSXM

LANGUAGE

ENGLISH

UNIT INVERSION

OFF

<SYSTEM INFORMATION>

 

<DISPLAY SETUP>

 

<UNIT SETTINGS>

 

<POSITION CALIBRATION>

 

RESET CAMERA

 

CYCLE CAMERA POWER

 

REBOOT SYSTEM

 

EXIT

 

 

 

 

 

 

 

 

 

 

UNIT SETTINGS

 

 

 

<CAMERA>

 

<MOTION>

 

<POWER UP>

 

<LINE SYNC>

 

<PRESETS>

 

<PATTERNS>

 

<ZONES>

 

<WINDOW BLANKING>

 

<ALARMS>

 

<WIPER>

 

<AUX>

 

<CLEAR>

 

<PASSWORD>

 

BACK

 

EXIT

 

 

 

 

 

 

 

 

ALARMS

 

 

 

 

 

 

 

 

RESUME

OFF

SEQUENCE (SECS)

5

RESET DELAY (SECS)

 

<ALARM SETTINGS>

 

BACK

 

EXIT

 

The ExSite IPSXM system has seven alarm inputs, which can be programmed as high, medium or low priority. When an alarm is received, an input signal to the unit triggers the user-defined action (go to preset, run pattern, etc.) programmed for the alarm.

There are three global alarm settings:

RESUME

This mode lets the system resume its previous activity (scan, pattern, or

 

previous position) after all alarms are cleared.

SEQUENCE

This is the time the system will perform an alarm activity when more than one

 

alarm of the same priority occurs at the same time.

RESET DELAY

This is the amount of time the system considers the alarm to be active after it

 

has physically cleared.

Use the following steps to program alarm settings.

1.Use the joystick to position the cursor beside ALARM SETTINGS. Press Iris Open.

2.Select the alarm number:

a.Use the joystick to position the cursor beside ALARM NUMBER.

b.Press Iris Open. The cursor moves to the right.

c.Move the joystick up or down to view selections. Press Iris Open to enter selection.