PELCO EXSITE IPSXM
LANGUAGE | ENGLISH |
| |||
UNIT INVERSION | OFF |
| |||
<SYSTEM INFORMATION> |
|
| |||
<DISPLAY SETUP> |
|
| |||
<UNIT SETTINGS> |
|
| |||
<POSITION CALIBRATION> |
|
| |||
RESET CAMERA |
|
| |||
CYCLE CAMERA POWER |
|
| |||
REBOOT SYSTEM |
|
| |||
EXIT |
|
| |||
|
|
|
|
| |
|
|
|
|
|
|
UNIT SETTINGS |
|
| |||
|
|
| |||
<CAMERA> |
|
| |||
<MOTION> |
|
| |||
<POWER UP> |
|
| |||
<LINE SYNC> |
|
| |||
<PRESETS> |
|
| |||
<PATTERNS> |
|
| |||
<ZONES> |
|
| |||
<WINDOW BLANKING> |
|
| |||
<ALARMS> |
|
| |||
<WIPER> |
|
| |||
<AUX> |
|
| |||
<CLEAR> |
|
| |||
<PASSWORD> |
|
| |||
BACK |
|
| |||
EXIT |
|
| |||
|
|
| |||
|
|
|
|
|
|
|
|
| |||
ALARMS |
|
| |||
|
|
| |||
|
|
|
|
|
|
RESUME | OFF |
| |||
SEQUENCE (SECS) | 5 |
| |||
RESET DELAY (SECS) |
|
| |||
<ALARM SETTINGS> |
|
| |||
BACK |
|
| |||
EXIT |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
ALARM SETTINGS
ALARM NUMBER | 1 |
ALARM PRIORITY | LOW |
ALARM ACTION | NONE |
ACTIVATE AUX | NO |
ALARM CONTACT | OFF |
BACK |
|
EXIT |
|
3.Select the alarm priority:
a.Use the joystick to position the cursor beside ALARM PRIORITY.
b.Press Iris Open. The cursor moves to the right.
c.Move the joystick up or down to view the available selections. Available settings include HIGH, MEDIUM, and LOW (default). If multiple alarms with different priorities are active at the same time, the dome will only go to the alarms with the highest priority.
d.Press Iris Open to enter selection.
HIGH | Alarm action takes highest priority and will override manual pan, |
| tilt, and zoom control. |
MEDIUM/LOW | Alarm action will not occur if an alarm occurs during manual pan, |
| tilt, and zoom control. |
4.Set the alarm action:
a.Use the joystick to position the cursor beside ALARM ACTION.
b.Press Iris Open. The cursor moves to the right.
c.Move the joystick up or down to view the available selections. The following are the settings for alarm action:
NONE | No action when alarm is triggered. |
PRESET | The system goes to the preset that is the same as the alarm |
| number. Preset 1 will go to Alarm 1. |
PATTERN 1 | The system runs pattern 1 when alarm is triggered. |
PATTERN 2 | The system runs pattern 2 when alarm is triggered. |
PATTERN 3 | The system runs pattern 3 when alarm is triggered. |
PATTERN 4 | The system runs pattern 4 when alarm is triggered. |
AUTO SCAN | The system starts auto scan operation when alarm is triggered. |
RANDOM SCAN | The system starts random scan operation when alarm is triggered. |
FRAME SCAN | The system starts frame scan operation when alarm is triggered. |
d.Press Iris Open to enter selection.
36 |
|