Position Calibration

PELCO EXSITE IPSXM

LANGUAGE

ENGLISH

UNIT INVERSION

OFF

<SYSTEM INFORMATION>

 

<DISPLAY SETUP>

 

<UNIT SETTINGS>

 

<POSITION CALIBRATION>

 

RESET CAMERA

 

CYCLE CAMERA POWER

 

REBOOT SYSTEM

 

EXIT

 

 

 

 

 

 

 

 

 

 

 

POSITION CALIBRATION

*** PRESET NOT DEFINED ***

<EDIT PRESET SCENE>

<CLEAR CALIBRATION PRESET> <RECAL USING CAL PRESET>

BACK

EXIT

REFERENCE INFORMATION

AZIMUTH

ELEVATION

ZOOM

Position calibration sets the preset reference point for all automatic positioning system movements. Before programming presets, patterns, zones, labels, and window blanking, program and document the position calibration point. The purpose of the calibration point is to restore all programmed settings quickly in the event the unit is replaced or refurbished.

The position calibration point should be an easily identifiable point of reference. Best practice suggests it be associated with a prominent landmark in the most common preset position.

To program the calibration preset:

1.Use the joystick to position the cursor beside POSITION CALIBRATION.

2.Press Iris Open. The Position Calibration menu appears on the monitor.

3.Use the joystick to position the cursor beside EDIT PRESET SCENE.

4.Press Iris Open.

5.Follow the directions displayed on the monitor.

Once the calibration preset is programmed, the system should not have to be recalibrated unless the unit is serviced or moved.

To recalculate the calibration preset:

1.Use the joystick to position the cursor beside POSITION CALIBRATION.

2.Press Iris Open. The Position Calibration menu appears on the monitor.

3.Use the joystick to position the cursor beside RECAL USING CAL PRESET.

4.Press Iris Open.

5.Follow the directions displayed on the monitor.

To clear the calibration preset:

1.Use the joystick to position the cursor beside POSITION CALIBRATION.

2.Press Iris Open. The Position Calibration menu appears on the monitor.

3.Use the joystick to position the cursor beside CLEAR CALIBRATION PRESET.

4.Press Iris Open.

5.Follow the directions displayed on the monitor.