LABEL POSITIONS

LABEL POSITIONS

SPECTRA IV

LANGUAGE

<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> ACK ALERT*

RESET CAMERA

CYCLE CAMERA POWER

REBOOT SYSTEM

EXIT

DISPLAY SETUP

PRESET LABEL

ZONE LABEL ZOOM AZIMUTH/ELEVATION DIRECTION ALARM MESSAGE DATE/TIME <LABEL POSITIONS>

RESTORE FACTORY DEFAULTS

BACK

EXIT

LABEL POSITION

[ZONE LABEL-------]

[PRESET LABEL-------]

[ALARM 1-------]

[ALERT MESSAGE-------]*

<TITLE TEXT>

SAVE AND EXIT

CANCEL AND EXIT

HELP

XXXo/-XXXo

NE

XXX.XX

XX/XX/YYYY 00:00

Labels can be placed anywhere on the monitor. This feature allows you to customize the appearance of your monitor screen.

The following labels are not set at fixed positions:

PRESET LABEL

ZONE LABEL

ALARM 1

ZOOM RATIO - XXX.XX

AZIMUTH1/ELEVATION2 - XXX°/-XX°

DIRECTION - NE

ALERT MESSAGE3*

TITLE TEXT

To set a label position:

1.Use the joystick to position the cursor beside a label.

2.Press Iris Open.

3.Use the joystick to move the label up, down, left, and/or right.

4.Press Iris Open.

5.Repeat steps 1 through 4 to position other labels.

6.Position the cursor next to Save and Exit. Press Iris Open to save settings and exit menu.

1Azimuth is the pan angle from 0° to 359°.

2Elevation is the tilt position from 0° (horizon) to -90°.

3The alert message is the warning displayed on the monitor if pressure, temperature, or dew point inside the dome reach unacceptable levels.

*This setting applies only to Pressurized Spectra IV dome systems.