Pelco IV SE manual Select the alarm priority

Models: IV SE

1 96
Download 96 pages 46.76 Kb
Page 67
Image 67
3.Select the alarm priority:

SPECTRA IV

LANGUAGE

<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> ACK ALERT*

RESET CAMERA

CYCLE CAMERA POWER REBOOT SYSTEM

EXIT

DOME SETTINGS

<CAMERA>

<MOTION> <POWER UP> <LINE SYNC> <PRESETS> <PATTERNS> <ZONES>

<WINDOW BLANKING>

<ALARMS>

<AUX>

<TITLE TEXT> <ALERT>* <CLEAR> <PASSWORD> <CLOCK> <EVENT>

BACK

EXIT

ALARMS

RESUME

SEQUENCE (SECS)

RESET DELAY (SECS)

<ALARM SETTINGS>

BACK

EXIT

ALARM SETTINGS

ALARM NUMBER

ALARM PRIORITY ALARM ACTION ACTIVATE AUX ALARM CONTACT <EDIT SCHEDULE>

BACK

EXIT

3.Select the alarm priority:

a.Use the joystick to position the cursor beside ALARM PRIORITY.

b.Press Iris Open. The cursor moves to the right.

c.Move the joystick up or down to view the available selections. Available settings include HIGH, MEDIUM, and LOW (default). If multiple alarms with different priorities are active at the same time, the dome will only go to the alarms with the highest priority.

d.Press Iris Open to enter selection.

HIGH

Alarm action takes highest priority and will override manual pan,

 

tilt, and zoom control.

MEDIUM/LOW

Alarm action will not occur if an alarm occurs during manual pan,

 

tilt, and zoom control.

4.Set the alarm action:

a.Use the joystick to position the cursor beside ALARM ACTION.

b.Press Iris Open. The cursor moves to the right.

c.Move the joystick up or down to view the available selections. The following are the settings for alarm action:

NONE

No action when alarm is triggered.

PRESET

Dome goes to the preset that is the same as the alarm number.

 

Preset 1 will go to Alarm 1.

PATTERN 1

Dome runs pattern 1 when alarm is triggered.

PATTERN 2

Dome runs pattern 2 when alarm is triggered.

PATTERN 3

Dome runs pattern 3 when alarm is triggered.

PATTERN 4

Dome runs pattern 4 when alarm is triggered.

PATTERN 5

Dome runs pattern 5 when alarm is triggered.

PATTERN 6

Dome runs pattern 6 when alarm is triggered.

PATTERN 7

Dome runs pattern 7 when alarm is triggered.

PATTERN 8

Dome runs pattern 8 when alarm is triggered.

AUTO SCAN

Dome starts auto scan operation when alarm is triggered.

RANDOM SCAN

Dome starts random scan operation when alarm is triggered.

FRAME SCAN

Dome starts frame scan operation when alarm is triggered.

d. Press Iris Open to enter selection.

*This setting applies only to Pressurized Spectra IV dome systems.

C3412M (9/06)