Pelco IV SE manual Set the auxiliary to activate

Models: IV SE

1 96
Download 96 pages 46.76 Kb
Page 68
Image 68
5.Set the auxiliary to activate:

SPECTRA IV

LANGUAGE

<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> ACK ALERT*

RESET CAMERA

CYCLE CAMERA POWER REBOOT SYSTEM

EXIT

DOME SETTINGS

<CAMERA>

<MOTION> <POWER UP> <LINE SYNC> <PRESETS> <PATTERNS> <ZONES>

<WINDOW BLANKING>

<ALARMS>

<AUX>

<TITLE TEXT> <ALERT>* <CLEAR> <PASSWORD> <CLOCK> <EVENT>

BACK

EXIT

ALARMS

RESUME

SEQUENCE (SECS)

RESET DELAY (SECS)

<ALARM SETTINGS>

BACK

EXIT

ALARM SETTINGS

ALARM NUMBER

ALARM PRIORITY ALARM ACTION ACTIVATE AUX ALARM CONTACT <EDIT SCHEDULE>

BACK

EXIT

5.Set the auxiliary to activate:

a.Use the joystick to position the cursor beside ACTIVATE AUX.

b.Press Iris Open. The cursor moves to the right.

c.Move the joystick up or down to view the following available selections.

NO (default)

Not activated.

1

An alarm action will close AUX 1.

2

An alarm action will close AUX 2.

d. Press Iris Open to enter selection.

NOTE: The AUX 1/AUX2 will stop when all the alarms assigned to it have cleared. If the AUX1/AUX is set up as momentary, then it will be activated each time a new alarm is acti- vated.

6.Set the alarm contact:

a.Use the joystick to position the cursor beside ALARM CONTACT.

b.Press Iris Open. The cursor moves to the right.

c.Move the joystick up or down to view the following available selections.

N/O (default)

Normally open

N/C

Normally closed

d. Press Iris Open to enter selection.

NOTE: The alarm contact feature is functional and available for 16X and 23X models only if the dome drive is installed in a Spectra III SE or Spectra IV SE back box.

7.To edit the alarm schedule:

The Edit Schedule menu is a duplicate of the Edit Event menu in the Event section with the following exceptions. In the Edit Schedule menu, the event type cannot be changed. Also, the Holiday feature cannot be accessed from the Edit Schedule menu.

For instructions on changing the features in the Edit Schedule menu, refer to the Edit Event menu in the Event section.

*This setting applies only to Pressurized Spectra IV dome systems.

68

C3412M (9/06)

Page 68
Image 68
Pelco IV SE manual Set the auxiliary to activate