Pelco IV SE manual Alarms

Models: IV SE

1 96
Download 96 pages 46.76 Kb
Page 66
Image 66
ALARMS

ALARMS

SPECTRA IV

LANGUAGE

<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> ACK ALERT*

RESET CAMERA

CYCLE CAMERA POWER REBOOT SYSTEM

EXIT

DOME SETTINGS

<CAMERA>

<MOTION> <POWER UP> <LINE SYNC> <PRESETS> <PATTERNS> <ZONES>

<WINDOW BLANKING> <ALARMS>

<AUX>

<TITLE TEXT> <ALERT>* <CLEAR> <PASSWORD> <CLOCK> <EVENT>

BACK

EXIT

ALARMS

RESUME

SEQUENCE (SECS)

RESET DELAY (SECS)

<ALARM SETTINGS>

BACK

EXIT

ALARM SETTINGS

ALARM NUMBER

ALARM PRIORITY ALARM ACTION ACTIVATE AUX ALARM CONTACT <EDIT SCHEDULE>

BACK

EXIT

The Spectra IV SE dome systems have seven alarm inputs that can be programmed as high, medium, or low priority. When an alarm is received, an input signal to the dome triggers the user- defined action (go to preset, run pattern, etc.) programmed for the alarm.

NOTE: Refer to the notation in step 6 for the limited alarm features available for 16X and 23X models.

There are three global alarm settings:

RESUME

This mode lets the dome resume its previous activity (scan, pattern, or

 

previous position) after all alarms are cleared.

SEQUENCE

This is the time the dome will perform an alarm activity when more than one

 

alarm of the same priority occurs at the same time.

RESET DELAY

This is the amount of time the dome considers the alarm to be active after it

 

has physically cleared.

Use the following steps to program alarm settings.

1.Use the joystick to position the cursor beside ALARM SETTINGS. Press Iris Open.

2.Select the alarm number:

a.Use the joystick to position the cursor beside ALARM NUMBER.

b.Press Iris Open. The cursor moves to the right.

c.Move the joystick up or down to view selections. Press Iris Open to enter selection.

*This setting applies only to Pressurized Spectra IV dome systems.

66

C3412M (9/06)

Page 66
Image 66
Pelco IV SE manual Alarms