SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION> <DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER REBOOT SYSTEM
EXIT
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC> <PRESETS> <PATTERNS> <ZONES>
<WINDOW BLANKING> <ALARMS>
<AUX>
<TITLE TEXT> <ALERT>* <CLEAR> <PASSWORD> <CLOCK> <EVENT>
BACK
EXIT
MOTION
AUTO FLIP PROPORTIONAL PAN PARK TIME (MINUTES)
PARK ACTION SCAN SPEED (DEG/S) PRESET FREEZE FRAME
LIMIT STOPS
<SET MANUAL STOPS> <CLEAR MANUAL STOPS> <SET SCAN STOPS> <CLEAR SCAN STOPS>
<SET AZIMUTH ZERO> <CLEAR AZIMUTH ZERO>
BACK
EXIT
REFERENCE INFORMATION MANUAL LIMITS SET SCAN LIMITS SET
PARK TIME
This feature allows the dome to begin a specified operation (scan, preset, or pattern) after a programmed time of inactivity.
Park time can be programmed from 1 minute to 720 minutes (12 hours), or set to zero, which disables this feature. The default setting is zero.
Park Action
This feature will define the activity when the dome parks. The following settings are available:
NONE (default) | No action. |
AUTO SCAN | Dome starts auto scan operation. |
RANDOM SCAN | Dome starts random scan operation. |
FRAME SCAN | Dome starts frame scan operation. |
PRESET 1 | Dome goes to preset 1. |
PRESET 8 | Dome goes to preset 8. |
PATTERN 1 | Dome runs pattern 1. |
PATTERN 2 | Dome runs pattern 2. |
PATTERN 3 | Dome runs pattern 3. |
PATTERN 4 | Dome runs pattern 4. |
PATTERN 5 | Dome runs pattern 5. |
PATTERN 6 | Dome runs pattern 6. |
PATTERN 7 | Dome runs pattern 7. |
PATTERN 8 | Dome runs pattern 8. |
(Only 22X and 35X models allow PATTERN 2 through PATTERN 8.)
*This setting applies only to Pressurized Spectra IV dome systems.
C3412M (9/06) | 49 |