Philips DMR-XS350EB Power, Displays, 120, Display is dim Change Unit’s Display in the Setup menu

Models: DMR-XS350EB

1 140
Download 140 pages 28.41 Kb
Page 120
Image 120

Troubleshooting Guide

General Issues

 

Power

 

 

 

 

 

 

 

Page

 

 

 

 

No power.

 

• Insert the AC mains lead securely into a known active household mains

10, 11

The unit does not turn on pressing

socket.

 

• Linked timer recordings with external equipment is in recording standby

62

[^].

 

 

 

 

(“EXT-L” on the unit’s display blinks when [^] is pressed). Press [EXT LINK] to

 

 

 

 

 

 

 

 

cancel the recording standby.

 

 

 

 

 

The unit switches to standby

 

• One of the unit’s safety devices is activated. Press [8] on the main unit to

mode.

 

turn the unit on.

 

 

 

 

 

The unit is turned in standby

 

• If you connected this unit to an “HDAVI Control” compatible TV with an HDMI

84

automatically.

 

cable, or connected this unit to a Q Link-compatible TV with a fully wired 21-

 

 

 

 

pin Scart cable, this unit will be automatically set to standby mode when the

 

 

 

 

TV is set to standby mode.

 

 

 

 

This unit turns off when the TV

• If connected with an HDAVI Control 4 compatible TV (VIERA) with the

input is switched.

 

“Intelligent Auto Standby” setting activated on the TV, when switching the TV

 

 

 

 

input, the unit will be automatically turned to standby. For details please read

 

 

 

 

the operating instructions of the TV.

 

 

 

 

 

 

 

General Issues

 

Displays

 

 

Page

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The display is dim.

 

• Change “Unit’s Display” in the Setup menu.

101

 

 

 

 

 

 

 

 

 

 

 

 

“0:00” is flashing on the unit’s

 

• Set the clock.

15

display.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The displayed time of this unit is

• Times shown may disagree with actual times.

different from the actual recording

-R

 

-R DL

 

+R

 

+R DL

The remaining capacity does not increase even if titles

time or MP3 recording time.

 

 

are deleted.

 

 

 

 

• Available space on a DVD-RW (DVD-Video format) or +RW disc increases

 

 

 

when you delete the last title (space may increase slightly when you delete

 

 

 

 

other titles).

 

 

 

 

• If you record or edit about 200 times or more, the remaining capacity of DVD-

 

 

 

R, DVD-R DL, +R, and +R DL is reduced and then recording or editing may

 

 

 

 

be disabled (for the second layer on DVD-R DL and +R DL, this happens after

 

 

 

 

about 60 times).

 

 

 

 

• While searching, the elapsed time may not be displayed accurately.

 

 

 

 

 

 

 

 

 

 

 

Compared to the actual recorded

• The displayed recording/play time is converted from the number of frames at

time, the elapsed time displayed

29.97 frames (equal to 0.999 seconds) to one second. There will be a slight

 

is less.

 

difference between the time displayed and the actual elapsed time (e.g.,

 

(Only when recording in NTSC)

actual one-hour elapsed time may display as approximately 59 minutes 56

 

seconds). This does not affect the recording.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The clock does not display on the

• Ensure “Power Save” is set to “Off”.

104

unit when switched to standby.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Available disc space display is

• Available disc space display may be different from actual. Varying may be

showing different from what was

large especially when recorded in DR mode.

 

used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120

RQT9431

Page 120
Image 120
Philips DMR-XS350EB operating instructions Power, Displays, 120, Display is dim Change Unit’s Display in the Setup menu