Operation

(Menu)

1 Password Enter Password

(ESC) (ESC)

2 System Mode Preference

3

System Info

(ESC)

 

 

(Top)

(Top)

 

4

System

(ESC)

 

Identification

5

Generator

(ESC)

 

Sensitivity

6

System

 

 

Diagnostics

(ESC)

 

 

3

1

Unit Time

3 10

AC Vout Ph. 1 -- N

3

19

Wout

3

2

Unit Date

3 11

AC Vout Ph. 2 -- N

3

20

Wout Ph. 1 -- N

3

3

Input Frequency

3 12

AC Iin Ph. 1 -- N

3

21

Wout Ph. 2 -- N

3

4

Output Frequency

3 13

AC Iin Ph. 2 -- N

3

22

% Full Load

3

5

Battery Volts

3 14

AC Iout Ph. 1 -- N

3

23

% Load 1

3

6

Run Time

3 15

AC Iout Ph. 2 -- N

3

24

% Load 2

3

7

Seconds on Batt.

3 16

VAout

3

25

Power Factor L1

3

8

AC Vin Ph. 1 -- N

3 17

VAout Ph. 1 -- N

3

26

Power Factor L2

3

9

AC Vin Ph. 2 -- N

3 18

VAout Ph. 2 -- N

 

 

 

4

1

Model Name

4 3

Serial Number

4

5

Software Version

4

2

Model Number

4 4

Date Manufactured

 

 

 

5

1

Low Frequency

5 5

Freq Glitch Count

5

9

Auto Freq Mode

5

2

High Frequency

5 6

Line Delta

5

10

Max Delta

5

3

Slew Rate

5 7

Transfer Delay

 

 

 

5

4

Phase Lock

5 8

Low AC Out Delay

 

 

 

6

1

RO Value

6 3

Runtime at EOT

 

 

 

6

2

Battery Results

6 4

DC Volts at EOT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7 1

1

Del. Before Restart

7 1

6

Relay Mask (1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7 System Control

 

 

 

 

7 1

Communication

 

 

 

7 1

2

Del. Before Shtdwn

7 1

7

Relay Mask (2)

 

 

 

 

 

 

 

 

 

 

Configuration

(ESC)

 

 

Config

(ESC)

7 1

3

Auto Restart

7 1

8

Inv. Relay Delay

 

 

 

 

 

 

 

 

 

 

 

 

 

7 1

4

Sleep Time

7 1

9

EPO Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7 1

5

Config. BestDock

7 1

10

Ext. Bypass Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7 2

1

Const. I Duration

7

2

6

Test Interval

 

 

 

 

 

 

 

 

 

7 2

Battery Config

 

 

 

7 2

2

Const. V Duration

7 2

7

Test Time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(ESC)

7 2

3

Eqlz. Chrg Duration

7 2

8

Maint. Chrg. Volts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7 2

4

Eqlz. Chrg Interval

7

2

9

Eqlz. Chrg. Volts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Top)

 

 

 

 

7 2

5

Inst. Eqlz. Duration

7

2

10 External Capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7 3

System Config

 

 

 

7 3

1

System VA Limit

7 3

4

Nominal AC Vout

 

 

 

 

 

 

 

 

(Top)

 

 

 

 

 

 

 

 

 

 

(ESC)

7 3

2

Number Phases

7 3

5

Redundancy Level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7 3

3

Nominal Frequency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Alarm

 

 

Set Points

(ESC)

9

Logs & History

(ESC)

 

 

 

 

(Top)

(Top)

 

8 1

Low Vout Alarm

8

3

Low Vbatt Alarm

8 5

High Vbatt Alarm

8 2

Model Number

8

4

Near Low Vbatt Alarm

8 6

Low Run Time Alarm

 

 

 

 

 

 

 

9 1

Inverter Log

 

 

 

 

 

 

 

(Logs 1 - 16)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9 2

Alarm Log

 

 

 

 

 

 

 

(Logs 1 - 16)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9 3

Clear Logs

 

 

 

 

 

 

10

System Tests

 

 

 

 

10 1

Battery Test

 

 

 

 

 

 

(ESC)

10 2

Fan Test

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

Parameters

 

 

 

 

Parameter No.

(ESC)

 

 

 

 

 

Figure 50. Powerware 9170 System Menu Map

68

Powerware® 9170 User's Guide ￿ LTM-1344 B Uncontrolled Copy