Pressure Systems, Inc.

NetScanner™ System (9016, 9021, & 9022) User’s Manual

(2)Notice from the above figures (Figure 5.3a and 5.3b) that the three PC boards (315, 316 or 339, and 317) are held together by standoffs and gold connector pins. If there is a need to take the boards apart, ensure that the gold connector pins do not get bent.

(3)Carefully remove the ribbon connection from the PC-317 to the PC-280 Microprocessor board. Remove the six (6) 4-40 Phillips-head screws from the standoffs. Gently remove the PC-317 board by pulling straight up on the gold connector pins. If the PC-317 multiplexer board is suspected of malfunctioning, it must be returned to the factory, since there are no field replaceable parts on the board.

(4)Unscrew the standoffs between the PC-316 (or PC-339) and PC-315 boards and gently remove the PC-316 (or PC-339) board by pulling straight up on the gold connector pins. If the PC-316 (or PC-339) Signal Conditioning board is suspected of malfunctioning, it must be returned to the factory, since there are no field replaceable parts on the board.

(5)The PC-315 Connector Interface board is soldered to the top plate and cannot be removed in the field. If the PC-315 board is suspected of malfunctioning, the entire top plate must be returned to the factory.

(6)After replacing malfunctioning printed circuit boards, reassemble the module in reverse order from that used in taking it apart. Ensure the ribbon connection from the PC-317 board to the PC-280 Microprocessor board is connected properly and that it is not crimped. Pin 1 of the ribbon cable has a red stripe while pin 1 on the PC-280 connector will contain a square solder pad.

(7)Carefully replace the Viton gasket around the top plate and replace the twelve (12) Phillips-head screws that secure the top plate to the scanner housing. Tighten the screws. Do not over-tighten; 7-9 inch-pounds should be sufficient.

(8)Test your scanner to ensure proper operation.

5.1.4 Replacement of Transducers

Model 9016 has internal DH200 pneumatic transducers, as well as an internal calibration manifold with associated valves and O-rings. All these elements occasionally require service or replacement as described in the following sections.

Following is a step-by-step procedure to replace a DH200 transducer in a Model 9016 Intelligent Pressure Scanner. Use the tools and follow the general warnings already described in Section 5.1.1.

5 - 10www.PressureSystems.com

Page 144
Image 144
Pressure Systems 9022 user manual Replacement of Transducers

9022 specifications

Pressure Systems 9022 is a state-of-the-art pressure management system designed for various industrial applications, offering unparalleled efficiency and reliability. This innovative system has become a benchmark in pressure technology, providing users with advanced control and monitoring features.

One of the main features of Pressure Systems 9022 is its ability to deliver precise pressure regulation. Utilizing advanced algorithms, the system continuously monitors pressure levels and adjusts them in real-time, ensuring optimal performance and safety. This feature is particularly beneficial in industries such as oil and gas, pharmaceuticals, and food processing, where maintaining specific pressure levels is crucial for product integrity and process efficiency.

The 9022 is also equipped with cutting-edge connectivity options. With built-in IoT capabilities, the system can be easily integrated into existing networks, allowing for remote monitoring and control. Users can access pressure data in real-time through a user-friendly interface, which enhances decision-making and reduces response times in case of irregular conditions.

Another standout characteristic is its robust construction. Designed to endure harsh environmental conditions, the Pressure Systems 9022 is built from high-grade materials that provide excellent resistance to wear and corrosion. This attribute ensures longevity and minimizes maintenance costs, making it an economical choice for businesses.

Moreover, the system incorporates various safety features. Automatic shut-off valves and alarms are integrated into the design to prevent overpressure situations, protecting both equipment and personnel. These built-in safeguards align with industry standards and promote a culture of safety within organizations.

The Pressure Systems 9022 also emphasizes energy efficiency. By optimizing the pressure regulation process, it reduces energy consumption, contributing to lower operational costs and a smaller environmental footprint. This focus on sustainability resonates with modern businesses looking to enhance their eco-friendly practices.

In conclusion, Pressure Systems 9022 stands out as a versatile, efficient, and reliable solution for pressure management. Its advanced features, durability, and commitment to safety make it a valuable asset for any industrial operation. By adopting this technology, organizations can enhance performance while ensuring compliance with safety regulations, ultimately leading to a more productive and sustainable operation.