The following guidelines should be used when installing pressure connections to all NetScannerSystem Intelligent Pressure Scanner modules.

!Always wear safety glasses when working with pressurized lines.

!Ensure that user input pressure will not exceed the proof pressure ratings of the corresponding instrument transducer. Applying excessive pressure to measurement inputs can permanently damage the pressure transducers.

!Ensure that all tubing material is rated for the expected pressure and environmental conditions. Failure to use the proper tubing material may result in ruptured lines and possible personal injury.

!Ensure all high pressure lines are properly secured.

!Place retaining springs over all bulge tube fittings to ensure pneumatic lines remain attached and leak free. Springs should be pushed down on connections so that half of the spring length extends past the tube bulge.

Warning: Introduction of contaminants or corrosive materials to the module pneumatic inputs may damage module transducers, manifolds, and O-ring seals.

Users of the 9021 and 9022 may proceed to Section 2.3.7 since these modules do not require any pneumatic connections to the module itself.

2.3.6.1RUN Mode Inputs

The standard pneumatic tubing plates (for the 9016) contain sixteen numbered pneumatic input channels. These numbered inputs are attached to corresponding pressure transducers inside the instrument and should be pneumatically attached to the pressure measurement points under test.

The standard tubing plate also contains an input labeled RUN REF. The RUN REF input is pneumatically connected to the reference side of all internal DH200 pressure transducers. The RUN REF connection is used for situations where all channels have one reference pressure. The reference pressure may be as high as 250 PSI (1720 kPa). This input may also be left unattached to provide atmospheric reference pressure.

When using instruments with the reference per channel option (true differential), two pneumatic inputs will be provided for every numbered channel. These inputs are labeled ‘P’ and ‘R’. The ‘P’ connection is the test pressure input. The ‘R’ connection is the transducer reference input pressure. Since each channel has its own reference pressure input, the RUN REF input is not provided on the true differential tubing plate.

2 - 8www.PressureSystems.com

Page 25
Image 25
Pressure Systems 9022 user manual

9022 specifications

Pressure Systems 9022 is a state-of-the-art pressure management system designed for various industrial applications, offering unparalleled efficiency and reliability. This innovative system has become a benchmark in pressure technology, providing users with advanced control and monitoring features.

One of the main features of Pressure Systems 9022 is its ability to deliver precise pressure regulation. Utilizing advanced algorithms, the system continuously monitors pressure levels and adjusts them in real-time, ensuring optimal performance and safety. This feature is particularly beneficial in industries such as oil and gas, pharmaceuticals, and food processing, where maintaining specific pressure levels is crucial for product integrity and process efficiency.

The 9022 is also equipped with cutting-edge connectivity options. With built-in IoT capabilities, the system can be easily integrated into existing networks, allowing for remote monitoring and control. Users can access pressure data in real-time through a user-friendly interface, which enhances decision-making and reduces response times in case of irregular conditions.

Another standout characteristic is its robust construction. Designed to endure harsh environmental conditions, the Pressure Systems 9022 is built from high-grade materials that provide excellent resistance to wear and corrosion. This attribute ensures longevity and minimizes maintenance costs, making it an economical choice for businesses.

Moreover, the system incorporates various safety features. Automatic shut-off valves and alarms are integrated into the design to prevent overpressure situations, protecting both equipment and personnel. These built-in safeguards align with industry standards and promote a culture of safety within organizations.

The Pressure Systems 9022 also emphasizes energy efficiency. By optimizing the pressure regulation process, it reduces energy consumption, contributing to lower operational costs and a smaller environmental footprint. This focus on sustainability resonates with modern businesses looking to enhance their eco-friendly practices.

In conclusion, Pressure Systems 9022 stands out as a versatile, efficient, and reliable solution for pressure management. Its advanced features, durability, and commitment to safety make it a valuable asset for any industrial operation. By adopting this technology, organizations can enhance performance while ensuring compliance with safety regulations, ultimately leading to a more productive and sustainable operation.