Q-Logic SANBOX2 manual ConnUnitSensorInfo, ConnUnitSensorMessage

Models: SANBOX2 SANBOX

1 252
Download 252 pages 38.11 Kb
Page 114
Image 114

5 – Fibre Alliance MIB Objects

A

Table 5-18. ConnUnitSensorStatus Return Values for Voltage Status

Switch Value

Return Value

 

 

Good

OK (3)

Bad

Failed (5)

Other

Unknown (1)

 

 

Table 5-19. ConnUnitSensorStatus Return Values for Fan Status

Switch Value

Return Value

 

 

Good

OK (3)

Bad

Failed (5)

Other

Unknown (1)

 

 

connUnitSensorInfo (1.3.6.1.3.94.1.8.1.5)

Miscellaneous static information about the sensor, such as its serial number.

Syntax

DisplayString

Access

read-only

Status

mandatory

Return Value

Always returns an empty string.

connUnitSensorMessage (1.3.6.1.3.94.1.8.1.6)

This describes the status of the sensor as a message. It may also provide more resolution on the sensor indication. For example, “Cover temperature 1503K, above nominal operating range” ::= { connUnitSensorEntry 6 }.

Syntax

DisplayString

Access

read-only

Status

mandatory

5-30

59047-03 B

Page 114
Image 114