Q-Logic SANBOX2 manual ConnUnitEventFilter Read Return Values

Models: SANBOX2 SANBOX

1 252
Download 252 pages 38.11 Kb
Page 103
Image 103

A

5 – Fibre Alliance MIB Objects

connUnitEventFilter (1.3.6.1.3.94.1.6.1.25)

This value defines the event severity that will be logged by this connectivity unit. All events of severity less than or equal to connUnitEventFilter are logged in connUnitEventTable.

Syntax

FcEventSeverity

Access

read-write

Status

mandatory

Return Value

The switch log level setting. Refer to the following tables for connUnitEvent- Filter values.

Table 5-6. connUnitEventFilter Read Return Values

Severity Levels

Return Value

 

 

Critical

Critical (4)

Warn

Warning (6)

Info

Info (8)

None

Unknown (1)

 

 

Table 5-7. connUnitEventFilter Control Write Values

Control Value

Result

 

 

Emergency (2)

Critical

Alert (3)

Critical

Critical (4)

Critical

Error (5)

Warn

Warning (6)

Warn

Notify (7)

Info

Info (8)

Info

Debug (9)

Info

 

 