Section 7
QLOGIC MIB Objects
This section covers the implementation details for the QLOGIC Management Information Bases
7.1
QLOGIC MIB Definitions
This MIB replaces the fcFxPortPhysTable module defined in
fcQxPortPhysAdminStatus (1.3.6.1.4.1.1663.1.3.10.1.1.3)
The desired state of the FxPort. A management station may place the FxPort in a desired state by setting this object accordingly. The testing(3) state indicates that no operational frames can be passed. When a Fabric Element initializes, all FxPorts start with fcQxPortPhysAdminStatus in the offline(2) state. As the result of either explicit management action or per configuration information accessible by the Fabric Element, fcQxPortPhysAdminStatus is then changed to either the online(1) or testing(3) states, or remains in the offline state.
Syntax
INTEGER {
online(1), - place port online offline(2), - take port offline testing(3) - initiate test procedures
}
Access
Status
current
Return Value
Refer to Table