6 – Fabric Element MIB Objects
A
Table 6-6 fcFxPortPHysOperStatus Return Values
Status | Return Value |
|
|
Diagnostic | testing (3) |
Down | linkfailure (4) |
|
|
fcFxPortPhysLastChange (1.3.6.1.2.1.75.1.2.2.1.3)
The value of sysUpTime at the time the FxPort entered its current operational status. A value of zero indicates that the FxPort's operational status has not changed since the agent last restarted.
Syntax
TimeStamp
Access
Status
current
Return Value
Unsupported. Always returns error status "NoSuchName".
fcFxPortPhysRttov (1.3.6.1.2.1.75.1.2.2.1.4)
The Receiver_Transmitter_Timeout value of the FxPort. This is used by the receiver logic to detect a loss of synchronization.
Syntax
Milliseconds
Access
Status
current
Return Value
The default RT_TOV parameter is: 100 (0x64). This is a global setting for the switch. If writing value to a port, all ports will reflect this new value.