A
5 – Fibre Alliance MIB Objects
connUnitStatus (1.3.6.1.3.94.1.6.1.6)
Overall status of the connectivity unit. The goal of this object is to be the single poll point to check the status of the connunit. If there is any other component that has warning, then this should be set to warning. any of these values may occur with any of the ConnUnitState values.
Syntax
INTEGER
Access
Status
mandatory
Return Value
Refer to Table
Table 5-3. Connectivity Unit Return Values
Status | Return Value |
|
|
If one power supply is reporting Bad and/ | warning (4) |
or not installed |
|
If both power supplies are reporting Bad | failed (5) |
and/or not installed |
|
If one or more cooling fan failed | warning (4) |
If all cooling fans failed | failed (5) |
If temperature status = "Warm" | warning (4) |
If temperature status = "Overheating" | failed (5) |
If any port down | warning (4) |
If POST failed | failed (5) |
If switch Offline or in Diagnostics mode | warning (4) |
|
|