A

5 – Fibre Alliance MIB Objects

connUnitSensorStatus (1.3.6.1.3.94.1.8.1.4)

The status indicated by the sensor.

Syntax

INTEGER {

unknown(1)

other(2) - the sensor indicates other than ok (warning or failure). ok(3) - the sensor indicates ok

warning(4) - the sensor indicates a warning failed(5) - the sensor indicates failure

}

Access

read-only

Status

mandatory

Return Value

Refer to the following tables for connUnitSensorStatus return values.

Table 5-16. ConnUnitSensorStatus Return Values for Board Temperature

Switch Value

Return Value

 

 

Normal

OK (3)

Warm

Warning (4)

Overheating

Failed (5)

Other

Unknown (1)

 

 

Table 5-17. ConnUnitSensorStatus Return Values for Fan Status

Switch Value

Return Value

 

 

Good

OK (3)

Bad

Failed (5)

Other

Unknown (1)

 

 