7 – QLOGIC MIB Objects
A
Table 7-1. fcQxPortPhysAdminStatus Read Return Values
Port | Value |
|
|
Online | online (1) |
Offline | offline (2) |
Diagnostics | testing (3) |
Down | offline (2) |
|
|
Refer to Table
Table 7-2. fcQxPortPhysAdminStatus Write Values
Port | Value |
|
|
Online | online (1) |
Offline | offline (2) |
Diagnostics | testing (3) |
|
|
fcQxPortPhysOperStatus (1.3.6.1.4.1.1663.1.3.10.1.1.4)
The current operational status of the FxPort. The testing(3) indicates that no operational frames can be passed. If fcQxPortPhysAdminStatus is offline(2), then fcQxPortPhysOperStatus should be offline(2). If fcQxPortPhysAdminStatus is changed to online(1), then fcQxPortPhysOperStatus should change to online(1). If the FxPort is ready to accept Fabric Login request from the attached NxPort, it should proceed and remain in the link- failure(4) state if, and only if, there is a fault that prevents it from going to the online(1) state.
Syntax
INTEGER {
online(1), - Login may proceed offline(2), - Login cannot proceed testing(3), - port is under test linkFailure(4) - failure after online/testing
}
Access
Status
current