3 – Configuring a Switch

A

cli #> admin start

cli (admin) #> set setup snmp

A list of attributes with formatting and current values will follow. Enter a new value or simply press the ENTER key to accept the current value. If you wish to terminate this process before reaching the end of the list press 'q' or 'Q' and the ENTER key to do so.

Trap Severity Options

---------------------

unknown, emergency, alert, critical, error, warning, notify, info,

debug, mark

(string, max=32 chars)

[True]

 

SnmpEnabled

 

Contact

(string, max=32 chars)

[<sysContact undefined> ]

Location

(string, max=32 chars)

[<sysLocation undefined>]

Trap1Address

(dot-notated IP Address)

[10.0.0.254

]

Trap1Port

(decimal value)

[162

]

Trap1Severity

(see allowed options above) [warning

]

Trap1Version

(1 / 2)

[2

]

Trap1Enabled

(True / False)

[False

]

Trap2Address

(dot-notated IP Address)

[0.0.0.0

]

Trap2Port

(decimal value)

[162

]

Trap2Severity

(see allowed options above) [warning

]

Trap2Version

(1 / 2)

[2

]

Trap2Enabled

(True / False)

[False

]

Trap3Address

(dot-notated IP Address)

[0.0.0.0

]

Trap3Port

(decimal value)

[162

]

Trap3Severity

(see allowed options above) [warning

]

Trap3Version

(1 / 2)

[2

]

Trap3Enabled

(True / False)

[False

]

Trap4Address

(dot-notated IP Address)

[0.0.0.0

]

Trap4Port

(decimal value)

[162

]

Trap4Severity

(see allowed options above) [warning

]

Trap4Version

(1 / 2)

[2

]

Trap4Enabled

(True / False)

[False

]

Trap5Address

(dot-notated IP Address)

[0.0.0.0

]

Trap5Port

(decimal value)

[162

]

Trap5Severity

(see allowed options above) [warning

]

Trap5Version

(1 / 2)

[2

]

Trap5Enabled

(True / False)

[False

]

ReadCommunity

(string, max=32 chars)

[public

]

WriteCommunity (string, max=32 chars)

[private

]

TrapCommunity

(string, max=32 chars)

[public

]

AuthFailureTrap(True / False)

[False

]

ProxyEnabled

(True / False)

[True

]

Do you want to save and activate this snmp setup? (y/n) [n] y SNMP setup saved and activated.

3-2

59047-03 B

Page 16
Image 16
Q-Logic SANBOX2 manual Configuring a Switch