| R |
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
| Reference Materials |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| When describing the location of a component |
|
|
Component Function |
| part it is always AS YOU FACE THE FRONT |
|
| |
| OF THE APPLIANCE. |
|
| ||
A.11 |
| E |
|
| |
1. Control Box |
|
|
|
| |
|
|
|
|
a. The control box is located on right side of appliance, behind the right side panel.
b. There is a light located inside of the control box. The internal light will turn green when the appliance has reached a temperature of 200οF (93°C) in the firepot. and will turn red when it reaches 600oF (315°C).
c.There is also an internal blue light located in the upper left corner of the control box. When you plug in the appliance the blue light will automatically start blinking 1 blink every 10 seconds for 60 seconds and then will stop.
NOTE:
Do NOT open the control box. This will void the warranty. If you need to plug in or remove the control box you must first unplug the appliance.
2.Convection Blower
The convection blower is mounted at the bottom rear of the appliance. There are 2 impellers, one on each side of the motor. The convection blower pushes heated air through the heat exchange system into the room.
3.Exhaust Blower
The exhaust blower is mounted on the left side of the appliance behind the left side panel. It is accessible either when the insert is pulled out onto the hearth or from both hinged side openings. The exhaust blower is designed to pull the exhaust from the appliance and push it out through the venting system.
4.Feed System
The feed system is located behind the firebox and can be removed as an entire assembly. The assembly includes the feed motor, mounting bracket, bearing and feed spring (auger). The hollow feed spring (auger) pulls pellets up the feed tube from the hopper area and drops them down the feed chute into the firepot.
5.Firepot
The firepot is made of high quality ductile iron and has a cleaning
6.Fuse
The fuse is located on the right side of the appliance behind the side panel. The fuse will blow should a short occur and shut off power to the appliance.
7.Heat Exchangers
The heat exchangers transfer heat from the exhaust system into convection air. There are 2 clean out rods located under the heat exchangers.
8.Heat Output Switch
The heat output switch is located on the right side of firebox, behind right side panel. The function of the heat output switch is to regulate the burn rates; low, medium and high settings.
9.Igniter
The igniter is mounted on the base of the firepot. Combustion air travels over the red hot igniter creating super heated air that ignites the pellets.
10.Junction Box And Wiring Harness
The junction box is located on the right side of the appliance, behind the right front access panel. The junction box and wiring harness are replaced as one component.
11.Power Supply
The power outlet is located on the right side of the appliance. Check the wall receptacle for 120 volt, 60 Hz (standard current). Make sure the outlet is grounded and has the correct polarity. A good surge protector is recommended. When operating with a generator you need at least 600 watts of power, or with an inverter at least 800 watts of power, available for the appliance during the start cycle.
12.Red Call Light
The red call light is on the right side behind the right side panel. The function of the red call light is to indicate that the thermostat is calling for heat.
13.Reset Button
The reset button is located on the right side of firebox behind right side panel. The function of the reset button is to momentarily open the thermostat circuit, which restarts the system.
14.Thermocouple
The thermocouple is located on top of the firepot inside the thermocouple cover (ceramic protection tube). The thermocouple sends a millivolt signal to the control box indicating the preset temperatures of the green and red lights have been obtained.
15.Thermostat
The appliance is designed to run on a 12 volt AC thermostat. The heat anticipator, if present, should be set on the lowest setting available.
October 26, 2006 | Page 35 |