Quadra-Fire CB1200I-B Appliance Set-Up, A.Rear Shroud Installation, CB1200-IPellet Insert

Models: CB1200I-B

1 44
Download 44 pages 51.43 Kb
Page 17
Image 17
Appliance Set-Up

 

R

CB1200-I Pellet Insert

 

 

 

 

 

 

7

Appliance Set-Up

 

 

 

A.Rear Shroud Installation

1.Top Vent Installations

Parts Required:

Part 811-0680, Rear Shroud Kit.

Includes: Six galvanized steel shroud pieces, two cover plates and fastener package.

Part 811-0650, Rear Shroud Top Vent

Includes: Vent pipe and two 1/4 - 20 x 3/4" bolts with nuts.

Part 811-0660, 3" Top Vent Adapter or Part 811-0670, 4” Top Vent Adapter

2.Rear vent installations Parts Required:

Part 811-0680, Rear Shroud Kit. Part 811-0690, Rear Vent Kit

Includes: Rear Vent Adapter and fastener package.

 

 

 

 

 

REAR SHROUD TOP

 

 

 

 

VENT PART 811-0650

 

 

 

 

 

 

Right Corner

Top Vent Opening

Left Corner

 

 

 

 

 

 

 

Left

Corner

 

 

Piece

 

Filler

 

 

 

-Out

Rear

Knock

Access

Vent

 

 

 

 

 

 

Outside

Air

Vent

 

 

 

 

 

Pipe

Access

 

 

 

 

 

Tools Required:

Electric drill, 1/8" drill bit, Phillips screw driver, 3/8" wrench & 7/16" wrench, (7/16" socket wrench & high temperature silicone adhesive are also required for rear vent installations).

Figure 17.1

Complete the following procedures, based on your venting installation, prior to installing the rear shroud kit. (Note: All photos depict top vent installation).

Top Vent Installation Preparation

Filler Piece

Figure 17.2

Rear Shroud

Top Vent

Figure 17.3

1.Remove the top vent adapter from the vertical exhaust transition pipe. Figures 17.2 and 17.5.

2.Use 2 screws to attach left corner filler piece of rear shroud to the insert hopper. Figures 17.1 and 17.2.

3.Use (2) 1/4 - 20 x 3/4" bolts with nuts to install rear shroud top vent to the exhaust transition. See boxed area in Figure 17.3. (Circled area, top vent adapter, will be installed later).

4.Install the left shroud panel corner at 3 points, 2 screws into back of hopper and 1 down into the filler piece).

Figure 17.4

Left Corner

Piece

Figure 17.4

Vertical Exhaust

Transition Pipe

Top Vent Adapter

Figure 17.5

October 26, 2006