CB1200-I Pellet Insert

R

16.Snap Disc #1 (Convection Blower) 125°F

Snap disc #1 is located on the right side of the firebox. There are 2 purple wires connected to it. This snap disc turns the convection blower on and off as needed. Power is always present at snap disc #1.

17.Snap Disc #2 (Fuel Delivery Interrupt) 200°F

Snap disc #2 is located on the back side of the feed drop tube. There is 1 orange wire and 1 black wire connected to it. This snap disc will turn off the feed system, which will turn off the appliance if an overfire condition should occur or if the convection blower should fail to operate. If this occurs the snap disc with automatically reset itself.

18.Snap Disc #3 (Burn Back Protector) 250°F

Snap disc #3 is mounted on the right side of the auger tube just below feed motor and has a reset button. To access it remove the right side panel. If the fire tries to burn back into the feed system or push exhaust up the feed tube, this snap disc will shut the entire system off. This disc must be manually reset.

19.Vacuum Switch

The vacuum switch is located at the rear of the appliance. This switch turns the feed system on when vacuum is present in the firebox. The vacuum switch is a safety device to shut off the feed motor if the exhaust or the heat exchanger system is dirty or plugged or if the firebox door is open.

20.Wiring Harness See Figure 36.1 below

T-STAT CONN (YEL)

T-STAT CONN

SNAP DISC #2 (YEL)

SNAP DISC #2 (YEL)

SNAP DISC # (GRAY)

SNAP DISC #1 (PUR)

SNAP DISC #1 (PUR)

POWER IN (BLK)

BLK

M BLK

CONV. BLOWER

 

 

 

 

 

WHITE

 

RED

AUGER MOTOR (RED/WHT)

 

 

 

 

 

M

AUGER MOTOR (BLK)

 

 

BLK

 

WHITE

 

 

VAC.

 

M BLK COMB BLOWER (BLU) SWITCH

 

 

BLK

NEUTRAL IN (WHT)

 

 

 

NEUTRAL AUGER

(WHT)

 

 

 

NEUTRAL CONV

(WHT)

 

 

 

NEUTRAL COMB

(WHT)

NEUTRAL IGN (HT)

IGNITER (HT)

Figure 36.1

AUG. CAP.

 

4

5

6

ACCY

 

 

 

 

 

1

2

3

JUMPER

 

 

 

 

 

 

BURN R ATE

 

 

 

 

BLUE

 

 

 

 

PURPLE

 

P.B.

LIGHT

ORANGE

 

 

 

 

GRAY

ORANGE

YELLOW

 

 

BLACK

 

 

 

 

HI-TEMP HI-TEMP BLUE GRAY PURPLE RED YELLOW YELLOW YELLOW BLUE WHITE ORANGE BLACK PURPLE RED

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

FUSE

.

RED

T.C

 

 

YELLOW

T/C

Page 36

7014-083C

October 26, 2006

Page 36
Image 36
Quadra-Fire CB1200I-B Snap Disc #1 Convection Blower 125F, Snap Disc #2 Fuel Delivery Interrupt 200F, Vacuum Switch