C. Tools And Supplies Needed

CB1200-I Pellet Insert

R

C. Tools And Supplies Needed

Tools and building supplies normally required for installation, unless installing into an existing masonry fireplace:

Reciprocating Saw

Safety Glasses

Hammer

Framing Square

Phillips Screw driver

Electric Drill & Bits (1/4”)

Tape Measure

1/4” Self-Tapping Screws

Plumb Line

May also need:

Level

Framing Material

Vent Support Straps

Hi-temp Caulking Material

Venting Paint

Gloves

 

D. Measuring Standards

1.Pipe measurements are from center line to center line.

2.Vertical terminations are measured to top of pipe.

Measure vertical

clearances from

this surface

Measure horizontal

clearances from

this surface

Figure 6.1

D. Measuring Standards WARNING

Inspect appliance and components for damage. Damaged parts may impair safe operation.

Do NOT install damaged components.

Do NOT install incomplete components.

Do NOT install substitute components.

Report damaged parts to dealer.

E. Inspect Appliance & Components and Pre-Use Check List

1.

 

Place the appliance in a location near the

 

 

final installation area and follow the proce-

 

 

dures below:

2.

 

Open the appliance and remove all the parts

 

 

and articles packed inside the Component

 

 

Pack. Inspect all the parts and glass for ship-

 

 

ping damage. Contact your dealer if any irregu-

 

 

larities are noticed.

3.

 

All safety warnings have been read and fol-

 

 

lowed.

4.

 

This Owner’s Manual has been read.

5.

 

Floor protection requirements have been met.

6.

 

Venting is properly installed.

7.

 

The proper clearances from the appliance and

 

 

chimney to combustible materials have been

 

 

met.

8.

 

The masonry chimney is inspected by a profes-

 

 

sional and is clean, or the factory built metal

 

 

chimney is installed according to the manufac-

 

 

turer’s instructions and clearances.

9.

 

The chimney meets the required minimum

 

 

height.

10.

 

All labels have been removed from the glass

 

 

door.

11.

 

Plated surfaces have been wiped clean, if

 

 

applicable.

12.

 

Thermostat or remote has been installed.

13.

 

A power outlet is available nearby.

Figure 6.1 WARNING

Fire Risk.

Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:

Installation and use of any damaged appliance.

Modification of the appliance.

Installation other than as instructed by Hearth & Home Technologies.

Installation and/or use of any component part not approved by Hearth & Home Technologies.

Operating appliance without fully assembling all components.

Do NOT Overfire.

Or any such action that may cause a fire hazard.