CB1200-I Pellet Insert

C. Full Reline With Outside Air

12” (05mm) min. above

12” (05mm) min. below

NOTE: Check clearances carefully for this type of installation to ensure adequate room for outside air venting.

NOTE: In Canada, only a full reline is allowed per ULC S-628, ORD ULC C1482.

CAUTION

Check building codes prior to installation.

Installation MUST comply with local, regional, state and national codes and regulations.

Consult local building, fire officials or authorities having jurisdiction about restrictions, installa- tion inspection, and permits.

NOTE; Use metal plate around exhaust vent pipe and seal all edges with non-flammable insulation such as fiberglass, mineral wool or ceramic.

Do not use high temperature caulk- ing materials to seal any edge to prevent furture serviceability.

Outside Air

Termination

at Chimney Top

Exit through the Ash Clean-Out of Masonry Chimney

Outside Air

through

Rear Wall

Figure 15.1

October 26, 2006

7014-083C

Page 15

Page 15
Image 15
Quadra-Fire CB1200I-B owner manual CB1200-I Pellet Insert Full Reline With Outside Air