Quadra-Fire CB1200I-B Venting Systems, A.5Direct Connect With Outside Air, CB1200-IPellet Insert

Models: CB1200I-B

1 44
Download 44 pages 51.43 Kb
Page 14
Image 14
Venting Systems

CB1200-I Pellet Insert

R

Venting Systems

 

A.5Direct Connect With Outside Air

B. Direct Connect Without Outside Air

NOTE: In Canada, only a full reline is allowed per ULC S-628, ORD ULC C1482.

Outside Air

through

Rear Wall

NOTE; Use metal plate around exhaust vent pipe and seal all edges with non-flammable insulation such as fiberglass, mineral wool or ceramic material.

Do not use high tempera- ture caulking materials to seal any edge to prevent future serviceability.

Figure 14.1

NOTE:

Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY.

Illustrations/diagrams are not drawn to scale.

Actual installation may vary due to individual design preference.

CAUTION

Never draw outside combustion air from:

Wall, floor or ceiling cavity

Enclosed space such as an attic or garage

Figure 14.2

WARNING

Fire Risk.

Inspection of Chimney:

Masonry chimney must be in good condition.

Meets minimum standard of NFPA 211

Factory-built chimney must be 6 inch (152mm) UL103 HT.

NOTE:

In Canada, where passage through a wall or partition of combustible construction is desired, the installation shall conform to CAN/CSA-B365.

Page 14

7014-083C

October 26, 2006

Page 14