2 Getting Started

R

CB1200-I Pellet Insert

 

 

 

 

2 Getting Started

 

A.Design, Installation & Location Considerations

1.Appliance Location

Consideration must be given to safety, convenience, traffic flow, and the fact that the appliance will need a chimney and chimney connector. It is a good idea to plan your installation on paper, using exact measurements for clearances and floor protection, before actually beginning the installation. If you are not using an existing chimney, place the appliance where there will be a clear passage for a factory-built listed chimney through the outside wall or ceiling and roof.

Check with your local building code agency before you begin your installation. Be sure local building codes do not supersede UL specifications and always obtain a building permit so that insurance protection benefits cannot be unexpectedly cancelled. If any assistance is required during installation, please contact your local dealer.

We recommend that a qualified building inspector and your insurance company representative review your plans before and after installation.

2. Thermostat Location

The thermostat’s location will have some effect on the appliance’s operation. When the thermostat is located close to the appliance, it may require a slightly higher temperature setting to keep the rest of the house comfortable. If the thermostat location is in an adjacent room or on a different floor level, you will notice higher temperatures near the appliance.

A.Design, Installation & Location Considerations CAUTION

Do NOT connect this unit to a chimney flue servicing another appliance.

Do NOT connect to any air distribution duct or system.

B. Fire Safety

Maintain the designated clearances to combustibles. Insu- lation must not touch the chimney. You must maintain the designated air space clearance around the chimney. This space around a chimney is necessary to allow natural heat removal from the area. Insulation in this space will cause a heat buildup, which may ignite wood framing. NOTE:

Clearances may only be reduced by means approved by the regulatory authority having jurisdiction.

To provide reasonable fire safety, the following should be given serious consideration:

1.Install at least one smoke detector on each floor of your home to ensure your safety. They should be located away from the heating appliance and close to the sleeping areas. Follow the smoke detector manufacturer’s placement and installation instructions, and be sure to maintain regularly.

2.A conveniently located Class A fire extinguisher to contend with small fires resulting from burning embers.

3.A practiced evacuation plan, consisting of at least 2 escape routes.

4.A plan to deal with a hopper fire as follows: In the event of a hopper fire:

a.Notify fire department.

b.Prepare occupants for immediate evacuation.

c.Close all openings into the appliance.

d.Unplug appliance.

e.While awaiting fire department, watch for ignition of adjacent combustibles from overheated vent pipe, hot embers or sparks from the chimney.

f.Pour a bucket of water into the appliance hopper.

B. Fire Safety WARNING

Fire Risk.

Do not operate appliance before reading and understanding operating instructions.

Failure to operate appliance properly may cause a house fire.

October 26, 2006

7014-083C