C.Minimum Clearances To Combustibles for Masonry and Zero Clearance Fireplaces

 

MANTEL

 

Face Trim

 

B

WALL

 

SIDE

C

 

A

 

E

D

Figure 9.1

 

 

Inches

Millimeters

A

Louvers to combustible

6

153

 

side wall

 

 

B

Insert top to mantel

12

305

C

Front Facing

3

76

D

Hearth Extension - Front

6

153

E

Hearth Extension - Sides

8

203

D.Minimum Opening for Masonry and Zero Clearance Fireplaces for Built-In Using Rear Shroud

B

C

A

 

 

D

Figure 9.2

NOTE: A Quadra-Fire floor protector (Part 811-0730) is available through your dealer to be used as a floor protector for the section under the insert body only. Floor protection to front and sides of insert unit must be supplied in addition to this part.

 

 

Inches

Millimeters

A

Rear Width

22

558

B

Depth

15-1/2

393

C*

Height - Top Vent

25-1/2

647

 

Height - Rear Vent

22-1/2

571

D

Front Width

29-1/4

743

*The size of your floor protector choice must be added to this dimension. If using Quadra-Fire floor protector, Part 811-0730, allow 1-1/2” (38mm).