C. Minimum Clearances To Combustibles for

CB1200-I Pellet Insert

R

C. Minimum Clearances To Combustibles for

E. Masonry Minimum Opening

Masonry and Zero Clearance Fireplaces

 

 

MANTEL

 

Face Trim

 

B

WALL

 

SIDE

C

 

A

 

E

D

Figure 10.1

 

 

Inches

Millimeters

A

Louvers to combustible

6

153

 

side wall

 

 

B

Insert top to mantel

12

305

C

Top to Face Trim

3

76

D

Hearth Extension - Front

6

153

E

Hearth Extension - Sides

8

203

D.Minimum Opening for Masonry and Zero Clearance Fireplaces for Built-In Using Rear Shroud

B

C

A

 

 

D

Figure 10.2

 

 

Inches

Millimeters

A

Rear Width

22

558

B

Depth

15-1/2

393

C*

Height - Top Vent

25-1/2

647

 

Height - Rear Vent

22-1/2

571

D

Front Width

29-1/4

743

B

C

 

 

A

 

D

 

Location

Inches

Millimeters

A

Rear Width

22

558

B

Depth

13

330

C

Height - Top Vent

19-1/2

495

D

Front Width

29-1/4

743

F. Floor Protection

1.Zero Clearance Installations*

It is necessary to install a floor protection of non-combus- tible material with a R value of 3.0 (1 inch [25mm] minimum thickness with a “k” value of 0.58) or a 1 inch (25mm) air space between insert base and hearth.

2.Non-Zero Clearance Installations*

A non-combustible floor protector is required with a mini- mum R value of 3.0 (1 inch [25mm] minimum thickness with a “k” value of 0.58) extending 6 inches (153mm) in front of the insert and 8 inches (203mm) to each side of the door opening.

* See alternate floor protection worksheet.

NOTE: A Quadra-Fire floor protector (Part 811-0730) is available through your dealer to be used as a floor protec- tor for the section under the insert body only. Floor protec- tion to front and sides of insert unit must be supplied in addition to this part.

*The size of your floor protector choice must be added to this dimension. If using Quadra-Fire floor protector, Part 811-0730, allow 1-1/2 inches (38mm).