CB1200-I Pellet Insert

B. Full Reline With Outside Air - Vertical

R

NOTE: Check clearances carefully for this type of instal- lation to ensure adequate room for outside air venting.

NOTE: In Canada only a full reline is allowed per ULC S628, ORD ULC C1482-M1990.

305mm min. above

305mm min. below

NOTE; Use metal plate around

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

exhaust vent pipe and seal all

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

edges with non-flammable insula-

 

 

 

 

Outside Air

 

 

 

 

tion such as fiberglass, mineral

 

 

 

 

 

 

 

 

wool or ceramic.

 

 

 

 

Termination

 

 

 

 

 

 

 

 

 

at

Do not use high temperature caulk-

 

 

 

 

Chimney Top

 

 

ing materials to seal any edge to

 

 

 

 

(Vertical)

 

 

prevent furture serviceability.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 16.1

NOTE: In Canada this fireplace insert must be installed with a continous chimney liner a 6 inch (152mm) in diam- eter extending from the fireplace insert to the top of the chimney. The chimney liner must conform to the Class 3 requirments of CAN/ULC-S635, Standard for Lining Systems for Extising Masonry or Factory-Built Chimneys and Vents, or CAN/ULC-S640, Standard for Lining Sys- tems for New Masonry Chimneys.

CAUTION

Check building codes prior to installation.

Installation MUST comply with local, regional, state and national codes and regulations.

Consult local building, fire officials or authorities having jurisdiction about restrictions, installation inspection, and permits.