Quadra-Fire CB1200I, CB1200MI-MBK E. Fire Characteristics, F. Feed Rate Adjustment Instructions

Models: CB1200MI-MBK CB1200I

1 52
Download 52 pages 35.16 Kb
Page 28
Image 28
E. Fire Characteristics

CB1200-I Pellet Insert

R

 

 

 

 

 

 

 

E. Fire Characteristics

 

 

WARNING

 

A properly adjusted fire with the heat output control switch set

 

on “HIGH” has a short active flame pattern that extends out

 

 

Fire Risk

 

of the firepot approximately 4 to 6 inches (102-105mm). If

 

Do NOT operate appliance:

 

the fire has tall flames with black tails and seems somewhat

 

• With appliance door open.

 

lazy, the feed rate will need to be reduced. If the fire is not 4

 

• Firepot floor open.

 

inches to 6 inches (102-105mm) tall, increase the feed rate.

 

• Cleaning slide plates open.

 

A medium and low setting will give a shorter flame. The flame

Do NOT store fuel:

 

will rise and fall somewhat. This is normal.

• Closer than required clearances to com-

 

F. Feed Rate Adjustment Instructions

bustibles to appliance

 

• Within space required for loading or ash

 

 

removal.

 

The feed adjustment control rod is factory set, and should

 

be adequate for most fuels. The set screw is located at the

 

bottom of the hopper and set loose at the factory so the fuel

 

adjustment control rod will slide by only loosening the wing

 

nut. Do not re-tighten bottom set screw.

 

However, if the flame height is too high or too low, you will

 

need to adjust the feed rate. Wait until the appliance has been

 

burning for 15 minutes before making your adjustments and

 

allow 15 minutes for feed adjustment to take effect.

 

1. Open the hopper lid and locate the fuel adjustment control

 

rod.

Back side of Firepot

2. Loosen the wing nut on the rod.

 

3. Adjust the fuel adjustment control rod towards the "+"

Firepot floor left open

symbol to increase the feed rate and flame height or

 

towards the "-" symbol, to decrease the feed rate and

Figure 28.1 - DO NOT LEAVE FIREPOT FLOOR OPEN

flame height. Make approximately 1/2 inch (13mm)

 

movements of rod at a time.

 

4. Re-tighten the wing nut.

G. Ignition Cycles

1.During each ignition cycle, it is normal to see some smoke in the firebox. The smoke will stop once the fire starts.

2.The convection blower will automatically turn on after your appliance has reached the set temperature. This blower transfers heat from your appliance into the room, and will continue to run after the thermostat has stopped calling for heat until the appliance has cooled down.

3.Occasionally the appliance may run out of fuel and shut itself down. When this happens, the red call light will be on. To restart it, fill the hopper and press the reset button. When you press the reset button the red call light will go out. Release the button and the light will come back on. You should see a fire shortly. If not, follow the instructions “Starting Your First Fire”.on this page.