Quadra-Fire CB1200I Listing and Code Approvals, A. Appliance Certification, D. Electrical Rating

Models: CB1200MI-MBK CB1200I

1 52
Download 52 pages 35.16 Kb
Page 4
Image 4
Listing and Code Approvals

CB1200-I Pellet Insert

Listing and Code Approvals

R

A. Appliance Certification

E. BTU & Efficiency Specifications

MODEL:

1200-I Pellet Insert

LABORATORY:

OMNI Test Laboratories, Inc

REPORT NO.

061-S-13-2

TYPE:

Solid Fuel Room Heater/Pellet Fuel

 

Burning Type Insert

STANDARD:

ASTM E1509-95, ULC S628-93, ULC

 

S610-M87, ULC S628-M93 and ULC/

 

ORD-C1482-M1990 Room Heater Pellet

 

Fuel Burning Type and (UM) 84-HUD,

 

Mobile Home Approved

Emissions Rating:

.9 grams/hr

*BTU Output:

14,000 - 40,000 / hr

Heating Capacity:

up to 2,500 sq. ft. depending

 

on climate zone

Hopper Capacity:

60-75 lbs

Fuel:

Wood Pellets or Shelled Corn

Shipping Weight:

243 lbs

*BTU output will vary, depending on the brand of fuel you use in your appliance. Consult your Quadra-Fire dealer for best results.

NOTE: This installation must conform with local codes. In the absence of local codes you must comply with the ASTM

E1509-95, ULC S628-93, ULC S610-M87, ULC/ORD-C- 1482-M1990, (UM) 84-HUD.

WARNING! Risk of Fire! Hearth & Home Technologies dis- claims any responsibility for, and the warranty and agency listing will be voided by the above actions.

B. Mobile Home Approved

This appliance is approved for mobile home installations when not installed in a sleeping room and when an outside combustion air inlet is provided. The structural integrity of the mobile home floor, ceiling, and walls must be maintained.

The appliance must be properly grounded to the frame of the mobile home and use only listed pellet vent, Class “L” or “PL” connector pipe. A Quadra-Fire Outside Air Kit must be installed in a mobile home installation.

Note: This appliance is also approved for installation into a shop.

C. Glass Specifications

This appliance is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass.

D. Electrical Rating

115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 Amps

NOTE: Some generator or battery back-up systems may not be compatable with the micro-processor elec- tronics on this appliance. Please consult the power supply manufacturer for compatable systems.

DO NOT:

Install or operate damaged appliance

Modify appliance

Install other than as instructed by Hearth & Home Technologies

Operate the appliance without fully assembling all components

Overfire

Install any component not approved by Hearth & Home Technologies

Install parts or components not Listed or approved. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.

For assistance or additional information, consult a qualified installer, service agency or your dealer.

NOTE: Hearth & Home Technologies, manufacturer of this appliance, reserves the right to alter its products, their specifications and/or price without notice.

Quadra-Fire is a registered trademark of Hearth & Home Technologies.

Page

7014-188B

February 3, 2010

Page 4
Image 4
Quadra-Fire CB1200I Listing and Code Approvals, A. Appliance Certification, E. BTU & Efficiency Specifications, Model