Quadra-Fire CB1200MI-MBK F. Igniter Replacement, G. Baffle Removal, CB1200-IPellet Insert

Models: CB1200MI-MBK CB1200I

1 52
Download 52 pages 35.16 Kb
Page 39
Image 39
F. Igniter Replacement

R

CB1200-I Pellet Insert

F. Igniter Replacement

G. Baffle Removal

Igniter Bracket

Thumb Screw

Igniter

Figure 39.1

a.Be sure the appliance is allowed to cool, has been unplugged and the exhaust blower is off.

b.Open glass door.

c.Grasp the bottom of the baffles and pull up to dis- lodge from hook attachment.

d.Use a standard screw driver to unlatch the covers beneath the baffles of each side.

e.Re-install in reverse order.

a.Be sure the appliance is allowed to cool, has been unplugged and the exhaust blower is off. Remove the ash pan.

b.The wire leads to the igniter are connected to the wire harness with 1/4 inch male / female spade connectors. These wires will pull forward approximately 4 to 5 inches (102mm to 127mm). Disconnect the spade connections and remove the igniter from the chamber. Loosen the thumb screw and slide igniter out.

c.Install new igniter into the chamber and tighten the thumb screw. Re-connect the wires to the 2 leads with the spade connectors.

d.Push excess wire leads to take-up the 4 to 5 inches (102mm to 107mm) previously pulled out. This will keep the wires out of the way of the ash pan. Double check that the igniter wires are clear of any movement, i.e. ash pan, firepot cleaning rod, etc.

f. Re-install the ash pan and re-connect the power.

February 3, 2010

7014-188B

Page 39

Page 39
Image 39
Quadra-Fire CB1200MI-MBK, CB1200I owner manual F. Igniter Replacement, G. Baffle Removal, CB1200-IPellet Insert