CB1200-I Pellet Insert
R
12.Door Gasket Inspection
•Frequency: Prior to heating season
•By: Homeowner
a.Be sure the appliance is allowed to cool, has been unplugged and the exhaust blower is off
b.To inspect the door rope (gasket), open the door and see that the door rope extends approximately 1/8 inch (3mm) to 3/16 inch (9.5mm) from the door rope chan- nel.
c.It should show signs of compaction all the way around the door where the rope contacts the face of the appli- ance. Confirm there are no air leaks.
13.Cleaning Exhaust Blower - Requires No Lubrication
•Frequency: Yearly or as needed
•By: Quality Service Technician/Homeowner
•Task:: Contact your local dealer.
14.Cleaning Convection Blower - Requires No Lubrication
•Frequency: Yearly or as needed
•By: Qualified Service Technician
•Task: Contact your local dealer.
15.Soot and Fly Ash: Formation & Need for Removal in Exhaust Venting System.
•Frequency: Yearly or more frequently depending on ash
•By: Qualified Service Technician/Homeowner
Be sure the appliance is allowed to cool, has been unplugged and the exhaust blower is off.
The products of combustion will contain small particles of fly ash. The fly ash will collect in the exhaust venting system and restrict the flow of the flue gases.
At
The venting system may need to be cleaned at least once a year or more often depending upon the quality of your fuel or if there is a lot of horizontal pipe sections. Ash will build up more quickly in the horizontal sections.
16.Preparing Firebox for Non-Burn Season
•Frequency: Yearly
•By: Homeowner
a.Be sure the appliance is allowed to cool, has been unplugged and the exhaust blower is off.
b.Remove all ash from the firebox and vacuum thoroughly.
c.Paint all exposed steel, including
•Use the
•Purchase paint from your local dealer.
•Must use a
Page 36 | February 3, 2010 |