Quadra-Fire CUMPGAP-PMH Cumberland Gap Wood Stove, B. Clearances To Combustibles UL And ULC

Models: CUMBGAP-MBK CUMPGAP-PMH

1 44
Download 44 pages 54.25 Kb
Page 10
Image 10
B. Clearances To Combustibles (UL And ULC)

R

Cumberland Gap Wood Stove

B. Clearances To Combustibles (UL And ULC)

B

A

E1

 

Non-fuel

 

C2

door side

C1

D2

 

 

 

D1

Fuel Door

 

Non-fuel

side

 

 

 

door side

 

 

F1

F2

E2

Fuel door

side

G(Ceiling)

G (Mantel)

Max Mantel Depth

10"

(254mm)

 

H

G (Ceiling)

IF SIDE FUEL LOADING DOOR IS NOT USED:

Must remain in the locked position at all times

Use clearances for non-fuel side door for both sides

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS: In Inches & (Millimeters)

NOTE: All "A" , "C" and "F" Dimensions are to the inside diameter of the flue collar.

TOP VENT VERTICAL

A

B

C1

C2

D1

D2

E1

E2

F1

F2

G

H

Single Wall-USA

13(330)

11.5(292)

27(686)

27(686)

18(457)

18(457)

16.5(419) 16.5(419)

20(508)

20(508)

56.5(1435)

N/A

Single Wall-Canada

13(330) 11.5(292)

27(686)

27(686)

18(457)

18(457)

16.5(419) 18(457)

20(508)

21.5(546)

56.5(1435)

N/A

Double Wall-USA

12(305) 10.5(267)

25(635)

26(660)

15(381)

16(406)

11(279)

16(406)

14(356)

19(483)

56.5(1435)

N/A

Double Wall-Canada

12(305) 10.5(267)

25(635)

28(711)

15(381)

18(457)

11(279)

18(457)

14(356)

21(533)

56.5(1435)

N/A

HORIZONTAL WITH MINIMUM 2FT (609mm) VERTICAL OFF STOVE TOP. (Note: Horizontal must be with 2ft (609mm) vertical and NOT directy off stove).

Single Wall-USA

13.5(343) 12(305)

27(686)

27(686)

17(432)

17(432)

N/A

N/A

N/A

N/A

42.5(1080)

10.5(267)

Single Wall-Canada

13.5(343) 12(305)

27(686)

28(711)

17(432)

18(457)

N/A

N/A

N/A

N/A

42.5(1080)

10.5(267)

Double Wall-USA

11(279)

9.5(241)

27(686)

27(686)

17(432)

17(432)

N/A

N/A

N/A

N/A

39(991)

8(203)

Double Wall-Canada

11(279)

9.5(241)

27(686)

28(711)

17(432)

18(457)

N/A

N/A

N/A

N/A

39(991)

8(203)

ALCOVE - Six inch (6") (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL103 HT listed factory-built Class "A"

 

chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.)

 

 

Min Height

 

 

 

 

 

 

Max Depth

Min Width

 

 

 

 

 

Front Door

48(1219)

55(1397)

 

72(1829)

 

 

 

 

Side Door-USA

48(1219)

57(1448)

 

72(1829)

 

 

 

 

Side Door-Canada

48(1219)

61(1549)

 

72(1829)

 

 

 

Double Wall-USA

12(305) 10.5(267)

25(635)

26(660)

15(381)

16(406)

N/A

N/A

N/A

N/A

44(1118)

N/A

Double Wall-Canada

12(305) 10.5(267)

25(635)

28(711)

15(381)

18(457)

N/A

N/A

N/A

N/A

44(1118)

N/A

REAR VENT INSTALLATIONS IN A MASONRY FIREPLACE OR THROUGH THE WALL . HORIZONTAL FLUE HEAT SHIELD, PART HTSHLD-7006, REQUIRED ON REAR VENT INSTALLATIONS: Six inch (6") (152mm) diameter listed double wall air insulated connector pipe with UL103 HT listed factory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor). Additional specifications include a MAXIMUM 10" (254mm) MANTEL WIDTH and the following clearances.

 

Double Wall-USA

N/A

12(305)

27(686)

27(686)

17.5(445)

17.5(445)

N/A

N/A

N/A

N/A

39(991) ceiling

N/A

 

Double Wall-Canada

N/A

12(305)

27(686)

27.5(699) 17.5(445)

18(457)

N/A

N/A

N/A

N/A

39(991) ceiling

N/A

 

 

 

 

 

 

USA or Canada -Single or Double Wall Pipe:

31(787) mantel

N/A

 

 

 

 

 

 

USA or Canada -Single or Double Wall Pipe: 24(610) mantel*

N/A

 

 

 

 

 

 

*with metal shield spaced 1" (25mm) away from bottom mantel surface

 

 

HEARTH MOUNT - SIDE DOOR MUST BE LOCKED CLOSED

 

 

 

 

 

 

 

 

 

Single Wall-USA

18(457)

10(254)

22(559)

31(787)

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

 

Single Wall-Canada

18(457)

10(254)

22(559)

31(787)

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Manual backgroundManual background NOTE: Optional Fire Screen, Part SCR-7006, can only be used in FULL Vertical installations

Page 10

7006-188G

November 5, 2010

Page 10
Image 10