6 Mobile Home Installation

R

Cumberland Gap Wood Stove

6 Mobile Home Installation

You must use a Quadra-Fire Outside Air Kit Part 831-1780 for installation in a mobile home.

1.An outside air inlet must be provided for combustion See page 17 for installation information.

2.Appliance must be secured to the mobile home structure by bolting the pedestal through hearth pad and into floor.

3.Appliance must be grounded with #8 solid copper grounding wire or equivalent and terminated at each end with N.E.C. approved grounding device.

4.Appliance must be installed with an approved UL103 HT ventilated chimney connector, UL103 HT chimney, and terminal cap with spark arrestor. Never use a single wall connector (stove pipe) in a mobile home installation. Use only double-wall connector pipe, Dura-Vent DVL, Selkirk metalbestos DS or Security DL double-wall connector or any listed double-wall connector pipe.

5.In Canada, this appliance must be connected to a 6 inch (152mm) factory-built chimney conforming to CAN/ULC-

629M, STANDARD FOR FACTORY BUILT CHIMNEYS.

6.Follow the chimney and chimney connector manufacturer’s instructions when installing the flue system for use in a mobile home.

7.Maintain clearance to combustibles.

8.Floor protection requirements must be followed precisely.

9.Use silicone to create an effective vapor barrier at the location where the chimney or other component penetrates to the exterior of the structure.

NOTE: Offsets from the vertical, not exceeding 45°, are allowed per Section 905(a) of the Uniform Mechanical Code (UMC). Offsets greater than 45° are considered horizontal and are also allowed, providing the horizontal run does not exceed 75% of the vertical height of the vent. Construction, clearance and termination must be in compliance with the UMC Table 9C. This installation must also comply with NFPA 211.

NOTE: Top sections of chimney must be removable to allow maximum clearance of 13.5 feet (411cm) from ground level for transportation purposes.

10.Burn wood only. Other types of fuels may generate poisonous gases (e.g., carbon monoxide).

11.If unit burns poorly while an exhaust blower is on in home, (i.e., range hood), increase combustion air.

12.Installation shall be in accordance with the Manufacturers Home & Safety Standard (HUD) CFR 3280, Part 24.

Spark Arrestor Cap

Storm Collar

Roof Flashing

Joist Shield/Firestop

Listed Chimney

Outside Air Kit

Connector

Floor Protector

Outside Air Floor Vent

Figure 23.1

CAUTION

THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/ROOF MUST BE MAIN- TAINED

Do NOT cut through:

Floor joist, wall, studs or ceiling trusses.

Any supporting material that would affect the structural integrity.

Manual background WARNING

Asphyxiation Risk.

NEVER INSTALL IN A SLEEPING ROOM.

Consumes oxygen in the room.

November 5, 2010

7006-188G