M. Correct Baffle & Blanket Placement

R

Cumberland Gap Wood Stove

M. Correct Baffle & Blanket Placement

INCORRECT POSITIONS

INCORRECT POSITIONS WARNING

Fire Risk

Firebox damage due to improper baffle place-

ment is not covered by warranty. Operate the wood burning appliance with the baffle in the correct position only.

Not doing so could result in:

Reduced efficiency

Overheating the chimney

Overheating the rear of the firebox

Poor performance

Ensure correct baffle placement and replace baffle com- ponents if damaged or missing.

These are generic drawings and may not represent your specific model.

CORRECT POSITION

Back of Firebox

Ceramic Blanket

Baffle Board

Ceramic Blanket and Baffle Board MUST be in contact with the back of the firebox and even with each other in the front.

Figure 31.1

Ceramic Blanket and Baffle Board are NOT in contact with the back of the firebox.

Ceramic Blanket is NOT in contact with the back of the firebox and NOT even with the Baf- fle Board in the front.

Back of Firebox

Ceramic Blanket

Baffle Board

Ceramic Blanket is bunched up at the back of the firebox and NOT even with the Baffle Board in the front.

Figure 31.2