C. Negative Pressure

R

Cumberland Gap Wood Stove

C. Negative Pressure

Draft is the pressure difference needed to vent appliances successfully. Considerations for successful draft include:

Preventing negative pressure

Location of appliance and chimney

Negative pressure results from the imbalance of air avail- able for the stove to operate properly. Causes for this imbal- ance include:

Exhaust fans (kitchen, bath) etc.)

Range hoods

Combustion air requirements for furnaces, water heaters and other combustion appliances

Clothes dryers

Location of return-air vents to furnace or air condi- tioning

Imbalances of HVAC air handling system

Upper level air leaks

Recessed lighting

Attic hatch opening

Duct leaks

To minimize the affects of negative air pressure the follow- ing must be considered:

Install the outside air kit. Install the intake on the side of the house towards prevailing winds during the heating season.

Ensure adequate outdoor air is supplied for combus- tion appliances and exhaust equipment.

Ensure furnace and air conditioning return vents are not located in the immediate vicinity of the appliance,

Avoid installing the appliance near doors, walkways or small isolated spaces.

Recessed lighting should be of “sealed can” design; attic hatches weather stripped or sealed; and attic mounted ductwork and air handler joints and seams taped or sealed.

WARNING

Asphyxiation Risk.

Negative pressure can cause spillage of combustion fumes, soot and carbon mon- oxide.

Appliance needs to draft properly for safety.

 

Recommended Location:

Recommended Location:

Above peak

• Above peak

Inside heated space

Marginal Location:

• Below peak

Marginal Location:

• Wind loading possible

Location NOT recommended:

Not the highest point of the roof

Wind loading possible

Windward

Recommended: Outside Air Intake on windward side

Recommended:

Insulated exterior chase in cooler climates

Multi-level Roofs

Location NOT recommended:

Too close to tree

Below adjacent structure

Lower roof line

• Avoid outside wall

Leeward

NOT recommended: Outside Air Intake on leeward side

Figure 6.1

Page 6

7006-188G

November 5, 2010