Quadra-Fire CUMBGAP-MBK warranty Cumberland Gap Wood Stove, Thimble, Components, Air Clearances

Models: CUMBGAP-MBK CUMPGAP-PMH

1 44
Download 44 pages 54.25 Kb
Page 19
Image 19
Components

R

Cumberland Gap Wood Stove

Thimble

Site constructed for masonry chimney installation:

Components

A minimum length of 12 inches [305mm] (longer for thicker walls) of solid insulated factory-built chimney length con- structed to UL 103 Type HT 6 inch (152mm) inside diam- eter. Chimney needs to extend a minimum of 2 inches (51mm) from the interior wall and a minimum of 1 inch

(25mm) from the exterior wall.

Wall spacer, trim collar and wall band to fit solid pack chimney selected.

Minimum 8 inch (203mm) diameter clay liner section (if not already present in chimney) and refractory mortar.

Air Clearances

Masonry chimney clearance must meet NFPA 211 mini- mum requirement of 2 inches (51mm) to sheet metal sup- ports and combustibles.

Minimum of 1 inch (25mm) clearance around the chimney connector.

Top of wall opening is a minimum of 13-1/2 inches (343mm) from ceiling or 4-1/2 inches (114mm) below minimum clearance specified by chimney connector man- ufacturer. NFPA 211 minimum vertical clearance of 18 inches (457mm) from chimney connector and ceiling or minimum recommended by chimney connector manufac- turer. Figure 19.1.

Instructions:

1.Open inside wall at proper height for the chimney con- nector to entry the masonry chimney. Figure 19.1

2.Entry hole to masonry chimney must be lined with an 8 inch (203mm) minimum diameter clay liner, or equiva- lent, secured with refractory mortar.

3.Construct a 17 inch x 17 inch (432mm x 432mm) outside dimension frame from 2 x 2 framing lumber to fit into wall opening. Inside opening of frame should be no less than 14 inch x 14 inch (356mm x 356mm). Figure 19.1.

4.Attach the wall spacer to the chimney side of the frame.

5.Nail the frame into the wall opening. The spacer should be on the chimney side.

6.Insert the section of the solid insulated chimney into the outer wall of the masonry chimney.

7.Tightly secure the length of the solid insulated chimney with the wall band to the masonry chimney.

8.Insert a section of chimney connector into the chimney. Make sure it does not protrude past the edge of the clay chimney liner inside the chimney.

9.Seal the end of the chimney connector to the clay liner with refractory mortar.

10.Install trim collar around the sold pack chimney section.

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ceiling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13.5” below ceiling to top

 

 

 

 

 

 

 

 

 

 

 

 

 

Wall

of opening

 

 

 

 

 

 

 

 

 

 

 

 

 

or top of opening is a min.of

 

 

 

 

 

Minimum18.0”

4.5” below min.clearance

 

 

 

 

 

NFPA

211

 

 

specified by connector mfg.

 

 

 

 

 

 

1.5

2x2 framing stud

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.0

min air clearance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.0

min air clearance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.5”

 

2.0”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.0”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17.0” OD 14.0” ID

8.0”

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.0”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.5”

 

2.0”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Center of Hole

 

 

 

 

 

 

 

 

 

 

 

Thimble

 

 

 

 

 

 

 

Include depth of hearth pad

Figure 19.1

 

 

Fire Clay Flue

 

 

Liner

 

 

with Airspace

 

 

Masonry

Trim Collar

 

Chimney

Chimney Section

 

Wall Spacer

 

 

with 2 inch

 

Wall Band to

(51mm)

 

 

Secure Chimney

Clearance to

 

 

Section

Combustibles

 

 

 

 

Chimney

Wood Studs Used

 

Connector

 

for Framing - Spaced

 

 

 

 

2 inch (51mm)

 

 

clearance from

 

 

Masonry Chimney

Figure 19.2 - Solid Pack Chimney with Metal Sup- ports as a Thimble

WARNING

Fire Risk.

Do NOT pack insulation or other combustibles between spacers.

ALWAYS maintain specified clearances around venting and spacers.

Install spacers as specified.

Failure to keep insulation or other material away from vent pipe may cause fire.

November 5, 2010

7006-188G

Page 19

Page 19
Image 19
Quadra-Fire CUMBGAP-MBK, CUMPGAP-PMH warranty Cumberland Gap Wood Stove, Thimble, Components, Air Clearances, Instructions