Image 13
Converting Collar For Rear Vent Installation

R

Cumberland Gap Wood Stove

B.Reversible Flue Collar and Horizontal Flue Heat Shield

Tools Required: Phillips head screwdriver; 3/8" and 7/16" wrench

The flue collar is reversible for either a top or rear venting installation. The appliance is shipped with the flue collar in the top vent position.

REQUIRED PARTS FOR REAR INSTALLATION:

Baffle Diverter: Shipped with appliance located inside firebox

Horizontal Flue Heat Shield, Part HTSHLD-7006: Not sup- plied, must be purchased from your local authorized dealer

Converting Collar For Rear Vent Installation

and

Installing Required Horizontal Flue Shield

Installing Required Horizontal Flue ShieldManual backgroundManual backgroundManual background Remove cast top

Remove bolts and

rotate flue collar

Manual backgroundDiscard heat shield

Rear Heat

Shield

Remove 4 screws and set rear shield & screws aside

Figure 13.1

1.Lift off cast top. Remove 4 Phillips head screws from the heat shield. Discard heat shield and save the screws.

Figure 13.1.

2.Remove 4 Phillips head screws from the rear shield, 2 on each side, lift shield off and set aside. Figure 13.1.

3.Remove 1 bolt from each side of the flue collar and retrieve nuts attached to bolts. Use 3/8" and 7/16" wrenches. Figure 13.1.

4.Turn vent to horizontal position. Inspect sealant to ensure a leak free application. Re-attach bolts. Figure 13.1.

5.Re-attach the rear heat shield.

6.Attach required accessory Horizontal Flue Shield with 2 of the screws removed in Step #1 and secure in place.

7.Follow instructions for placing the Baffle Diverter on pages 14 & 15.

8.Place cast top on the unit. See Figure 13.3 for completed view.

Secure

Horizontal Flue

Heat Shield

Figure 13.2

Figure 13.3 - Completed View