D. Chimney Termination Requirements

R

Cumberland Gap Wood Stove

D. Chimney Termination Requirements

Follow manufacturer’s instructions for clearance, securing flashing and terminating the chimney.

Must have an approved and Listed cap

Must not be located where it will become plugged by snow or other material

Must terminate at least 3 feet (91cm) above the roof and at least 2 feet (61cm) above any portion of the roof within 10 feet (305cm).

NOTE:

Chimney performance may vary.

Trees, buildings, roof lines and wind conditions affect performance.

Chimney height may need adjustment if smoking or overdraft occurs.

Must be located away from trees or other struc- tures

E.2-10-3 Rule

These are safety requirements and are not meant to assure proper flue draft.

Less than 10 ft. (305cm)

3 ft. (91cm)

Minimum

2 ft. (61cm)

10 ft. (305cm) To Nearest Roofline

2 ft. (61cm)

3 ft. (91cm)

Minimum

Pitched Roof

Figure 22.1

10 ft. (305cm) or more

Wall or Parapet

3 ft. (91cm) Minimum

3 ft. (91cm) Minimum

Less than 10 ft. (305cm)

2 ft. (61cm)Minimum

Figure 22.2

Flat Roof

 