Quadra-Fire QV32-A, QV36-A manual Approvals and Codes, Appliance Certification, Installation Codes

Models: QV32-A QV36-A

1 42
Download 42 pages 34.68 Kb
Page 8
Image 8
Approvals and

Approvals and

Codes

Appliance Certification

The Village Collection fireplace models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories.

Certification

MODELS: QV32-A, QV36-A

LABORATORY: Underwriters Laboratories

TYPE: Vented Gas Fireplace Heater

STANDARD: ANSI Z21.88•CSA2.33•UL307B

NOTE: THESE MODELS ARE UL LISTED TO UL307B, THE STANDARD FOR GAS-BURNING HEATING APPLI- ANCES FOR MANUFACTURED HOMES AND RECRE- ATIONAL VEHICLES.

Installation Codes

The fireplace installation must conform to local codes. Before installing the fireplace, consult the local building code agency to ensure that you are in compliance with all applicable codes, including permits and inspections.

In the absence of local codes, the fireplace installation must conform to the National Fuel Gas Code ANSI Z223.1 (in the United States) or the CAN/CGA-B149 Installation Codes (in Canada). The appliance must be electrically grounded in accordance with local codes or, in the absence of local codes with the National Electric Code ANSI/NFPA No. 70 (in the United States), or to the CSA C22.1 Canadian Electric Code (in Canada).

These models may be installed in a bedroom or bed-sitting room in the U.S.A. and Canada.

High Altitude Installations

U.L. Listed gas fireplaces are tested and approved for elevations from 0 to 2,000 feet in the U.S.A. and from 0 to 4,500 feet in Canada.

When installing this fireplace at an elevation above 2,000 feet (in the United States), it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Input should be reduced four percent (4%) for each 1,000 feet above sea level, unless the heating value of the gas has been reduced, in which case this general rule will not apply. To identify the proper orifice size, check with the local gas utility.

When installing this fireplace at an elevation between 2,000 and 4,500 feet (in Canada), the input rating must be reduced by ten percent (10%).

When installing this fireplace at an elevation above 4,500 feet (in Canada), check with local authorities.

Consult your local gas utility for assistance in determining the proper orifice for your location.

8

Page 8
Image 8
Quadra-Fire QV32-A, QV36-A Approvals and Codes, Appliance Certification, Installation Codes, High Altitude Installations