V |
| H |
1' MIN. (305mm) | 2' | MAX. (610mm) |
2' MIN. (610mm) | 4' | MAX. (1.22m) |
3' MIN. (914mm) | 6' | MAX. (1.86m) |
4' MIN. (1.22m) | 8' | MAX. (2.4m) |
V+H=40' MAX. (12.4m)
H = 8' MAX. (2.4m)
Use D-Series components only.
Note: There MUST be a 25% reduction in total H when using flex vent, except when using the simple up and out installation (see Figure 9).
V
H
Figure 12. Venting with One 90° Elbow
H
Use SL D-Series components only.
VENTING WITH ONE (1) 90o ELBOW NATURAL GAS | |
V (MIN.) | H (MAX.) |
90o Elbow on Top | 2 FT (610mm) |
1 FT (305mm) | 3 FT (914mm) |
2 FT (610mm) | 4 FT (1.22m) |
3 FT (914mm) | 6 FT (1.86m) |
4 FT (1.22m) | 8 FT (2.48m) |
5 FT (1.52m) | 16 FT (4.8m) |
H MAX. = 16 FT (4.8m) | V + H MAX. = 40 FT (12.2m) |
VENTING WITH ONE (1) 90o ELBOW | PROPANE | |
V (MIN.) | H (MAX.) |
|
90o Elbow on Top | NOT ALLOWED | |
1 FT (305mm) | 2 FT (610mm) | |
2 FT (610mm) | 4 FT (1.22m) | |
3 FT (914mm) | 6 FT (1.86m) | |
4 FT (1.22m) | 8 FT (2.48m) | |
5 FT (1.52m) | 16 FT (4.8m) |
H MAX. = 16 FT (4.8m)V + H MAX. = 40 FT (12.2m)
Figure 13. Venting with One 90° Elbow
18
V
Note: There MUST be a 25% reduction in total H when using flex vent, except when using the simple up and out installation (see Figure 9).