Quadra-Fire QV32-A, QV36-A manual Use SL D-Seriescomponents only, Venting with One 90 Elbow

Models: QV32-A QV36-A

1 42
Download 42 pages 34.68 Kb
Page 18
Image 18
Figure 12. Venting with One 90° Elbow

V

 

H

1' MIN. (305mm)

2'

MAX. (610mm)

2' MIN. (610mm)

4'

MAX. (1.22m)

3' MIN. (914mm)

6'

MAX. (1.86m)

4' MIN. (1.22m)

8'

MAX. (2.4m)

V+H=40' MAX. (12.4m)

H = 8' MAX. (2.4m)

Use D-Series components only.

Note: There MUST be a 25% reduction in total H when using flex vent, except when using the simple up and out installation (see Figure 9).

V

H

Figure 12. Venting with One 90° Elbow

H

Use SL D-Series components only.

VENTING WITH ONE (1) 90o ELBOW NATURAL GAS

V (MIN.)

H (MAX.)

90o Elbow on Top

2 FT (610mm)

1 FT (305mm)

3 FT (914mm)

2 FT (610mm)

4 FT (1.22m)

3 FT (914mm)

6 FT (1.86m)

4 FT (1.22m)

8 FT (2.48m)

5 FT (1.52m)

16 FT (4.8m)

H MAX. = 16 FT (4.8m)

V + H MAX. = 40 FT (12.2m)

VENTING WITH ONE (1) 90o ELBOW

PROPANE

V (MIN.)

H (MAX.)

 

90o Elbow on Top

NOT ALLOWED

1 FT (305mm)

2 FT (610mm)

2 FT (610mm)

4 FT (1.22m)

3 FT (914mm)

6 FT (1.86m)

4 FT (1.22m)

8 FT (2.48m)

5 FT (1.52m)

16 FT (4.8m)

H MAX. = 16 FT (4.8m)V + H MAX. = 40 FT (12.2m)

Figure 13. Venting with One 90° Elbow

18

V

Note: There MUST be a 25% reduction in total H when using flex vent, except when using the simple up and out installation (see Figure 9).

Page 18
Image 18
Quadra-Fire QV32-A, QV36-A manual Use SL D-Seriescomponents only, Venting with One 90 Elbow, Use D-Seriescomponents only